Comparative Analysis of Ultrasonography and MicroCT Imaging for Organ Size Evaluation in Mice

In this work, the authors compared microCT and in vivo ultrasonography in terms of accuracy and efficacy for measuring the volume of various organs in mice. Two quantification protocols were applied: ellipsoidal volume measuring maximum diameters in all three axes in both imaging systems and manual delineation of organ borders in microCT studies. The results were compared with ex vivo volumes. In general, both imaging techniques and quantification protocols are accurate, but ultrasound is faster in both acquisition and analysis. The only accurate method for heart volume measurement is manual segmentation on microCT. For the ovary, none of the techniques and protocols had a positive correlation with ex vivo volume. The three-diameter method can be used for ellipsoid organs because of its rapidity, but for more irregular structures, manual segmentation is recommended, although it is time-consuming.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2025-06-18
DOI
https://doi.org/10.3390/jimaging11060200
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Ultrasonography and MicroCT Imaging for Organ Size Evaluation in Mice

Marina Ferrer, Juan A. Cámara, Juan Jose Jimenez Catalan
Journal of Imaging
Radiomics and Machine Learning in Medical Imaging
article

Comparative Analysis of Ultrasonography and MicroCT Imaging for Organ Size Evaluation in Mice

Marina Ferrer, Juan A. Cámara, Juan Jose Jimenez Catalan
article en

Abstract

In this work, the authors compared microCT and in vivo ultrasonography in terms of accuracy and efficacy for measuring the volume of various organs in mice. Two quantification protocols were applied: ellipsoidal volume measuring maximum diameters in all three axes in both imaging systems and manual delineation of organ borders in microCT studies. The results were compared with ex vivo volumes. In general, both imaging techniques and quantification protocols are accurate, but ultrasound is faster in both acquisition and analysis. The only accurate method for heart volume measurement is manual segmentation on microCT. For the ovary, none of the techniques and protocols had a positive correlation with ex vivo volume. The three-diameter method can be used for ellipsoid organs because of its rapidity, but for more irregular structures, manual segmentation is recommended, although it is time-consuming.

Journal of ImagingVol. 11(6)
University of California, San Francisco (US), Vall d'Hebron Institut de Recerca (ES), Vall d'Hebron Institute of Oncology (ES)
National Institutes of Health, University of California, San Francisco, National Cancer Institute
Openalex Percentile: Top 79%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative Analysis of Ultrasonography and MicroCT Imaging for Organ Size Evaluation in Mice — Marina Ferrer, Juan A. Cámara, et al. · Journal of Imaging (2025) | TGRS Research Map | TGRS