Three-dimensional biomechanical analysis of flexible intramedullary nailing constructs in length-unstable pediatric femur fractures

Flexible intramedullary nail fixation of pediatric femoral shaft fractures offers advantages such as shorter hospital stays, faster return to function, and less associated costs when compared with traction and casting. This study compared the biomechanical performance of three configurations: 2CS, 2CL, and 3CL. Thirty synthetic femur models with identical, length-unstable, spiral fractures were tested using a three-dimensional camera system to assess real-time micromotion. Three groups were analyzed: (a) 2CS - two 3.5 mm C- and S-shaped nails inserted anterograde, (b) 2CL - one 'C' and one 'S' shaped 3.5 mm titanium nail-inserted retrograde from a single lateral entry, (c) 3CL - two 'C' shaped 3.5 mm titanium nails inserted medially and laterally with a third 'C' shaped 2.5 mm nail placed retrograde from an anterolateral site. Torsional loading, cyclical loading, and load-to-failure tests were conducted. The 3CL configuration demonstrated superior biomechanical performance. It exhibited the highest torsional stiffness [0.67 ± 0.06 Nm/° for external rotation (ER), 0.404 = ± 0.06 Nm/° for internal rotation (IR); P = 0.002], least displacement (0.05 ± 0.02 vs. 0.30 ± 0.02 mm for 2CL and 0.57 ± 0.05 mm for 2CS; P = 0.012), and required the highest load-to-failure (162 ± 83 vs. 106 4 ± 75 N for 2CL and 790 ± 34 N for 2CS; P = 0.016).The 3CL configuration provided superior strength and stability across all tests, supporting its role in the fixation of length-unstable pediatric femoral fractures.

Authors

Institutions

Publication Details

Journal
Journal of Pediatric Orthopaedics B
Published
2025-06-18
DOI
https://doi.org/10.1097/bpb.0000000000001267
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-dimensional biomechanical analysis of flexible intramedullary nailing constructs in length-unstable pediatric femur fractures

Jeremy P. Doak, M. Bryant Transtrum, Mark T. Ehrensberger, Emmanouil Grigoriou et al.
Journal of Pediatric Orthopaedics B
Bone fractures and treatments
article

Three-dimensional biomechanical analysis of flexible intramedullary nailing constructs in length-unstable pediatric femur fractures

Jeremy P. Doak, M. Bryant Transtrum, Mark T. Ehrensberger, Emmanouil Grigoriou, Emil Varas‐Rodríguez, Akshay Deshpande
article en

Abstract

Flexible intramedullary nail fixation of pediatric femoral shaft fractures offers advantages such as shorter hospital stays, faster return to function, and less associated costs when compared with traction and casting. This study compared the biomechanical performance of three configurations: 2CS, 2CL, and 3CL. Thirty synthetic femur models with identical, length-unstable, spiral fractures were tested using a three-dimensional camera system to assess real-time micromotion. Three groups were analyzed: (a) 2CS - two 3.5 mm C- and S-shaped nails inserted anterograde, (b) 2CL - one 'C' and one 'S' shaped 3.5 mm titanium nail-inserted retrograde from a single lateral entry, (c) 3CL - two 'C' shaped 3.5 mm titanium nails inserted medially and laterally with a third 'C' shaped 2.5 mm nail placed retrograde from an anterolateral site. Torsional loading, cyclical loading, and load-to-failure tests were conducted. The 3CL configuration demonstrated superior biomechanical performance. It exhibited the highest torsional stiffness [0.67 ± 0.06 Nm/° for external rotation (ER), 0.404 = ± 0.06 Nm/° for internal rotation (IR); P = 0.002], least displacement (0.05 ± 0.02 vs. 0.30 ± 0.02 mm for 2CL and 0.57 ± 0.05 mm for 2CS; P = 0.012), and required the highest load-to-failure (162 ± 83 vs. 106 4 ± 75 N for 2CL and 790 ± 34 N for 2CS; P = 0.016).The 3CL configuration provided superior strength and stability across all tests, supporting its role in the fixation of length-unstable pediatric femoral fractures.

Journal of Pediatric Orthopaedics BVol. 34(6)
Mayo Clinic (US), University at Buffalo, State University of New York (US)
Openalex Percentile: Top 80%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.