Evaluasi Kinerja Cooler #1533 Pada Unit Distilasi #1500 PT. X

PT. X is a company that produces the first Hydrogen Peroxide (H2O2) in Indonesia. The raw materials used in producing hydrogen peroxide (H2O2) at PT X are hydrogen (H2), oxygen (O2), water (H₂O) and supporting raw materials, namely WS (working solution), catalyst, stabilizer and ethylene. In the process of making hydrogen peroxide there are many stages in order to get the results on demand. This certainly requires supporting tools in the process such as coolers. The special task carried out is “Evaluation of Cooler #1533 Performance at Distillation Unit #1500 PT. X. Based on the calculation, the Rd value and %heat efficiency for 5 days tend to fluctuate. The Rd value ranges from 0.00094832 btu/hr.ft2.ᵒF to 0.002121257 btu/hr.ft2 .ᵒF, while the heat efficiency value ranges from 48% to 51%. The HE evaluation results on the 31st have the highest Rd value of 0.00212157 btu/hr.ft2 .ᵒF) so that the resulting heat efficiency value is 50%. While the HE evaluation results on the 28th have the lowest Rd value of 0.00094832 (btu/hr.ft2.ᵒF) so that it has the highest efficiency of 51%. The overall head coefficient (Uc) value is greater than the design overall coefficient (Ud) which indicates that the heat transfer in a clean state is higher than in a dirty state, so it can be said that cooler #1533 is still in a state worth using. The ΔP value for the shell has a value of 0.086605283 Psi and the ΔP value on the tube is 0.007 Psi range. This value is still below the standard value allowed, which is 10 Psi.

Authors

Publication Details

Journal
Jurnal Mekanova Mekanikal Inovasi dan Teknologi
Published
2025-05-03
DOI
https://doi.org/10.35308/jmkn.v11i1.11384
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluasi Kinerja Cooler #1533 Pada Unit Distilasi #1500 PT. X

Aulia Wahyuningtyas, Dinda Laras Ayu
Jurnal Mekanova Mekanikal Inovasi dan Teknologi
Engineering and Technology Innovations
article

Evaluasi Kinerja Cooler #1533 Pada Unit Distilasi #1500 PT. X

Aulia Wahyuningtyas, Dinda Laras Ayu
article en

Abstract

PT. X is a company that produces the first Hydrogen Peroxide (H2O2) in Indonesia. The raw materials used in producing hydrogen peroxide (H2O2) at PT X are hydrogen (H2), oxygen (O2), water (H₂O) and supporting raw materials, namely WS (working solution), catalyst, stabilizer and ethylene. In the process of making hydrogen peroxide there are many stages in order to get the results on demand. This certainly requires supporting tools in the process such as coolers. The special task carried out is “Evaluation of Cooler #1533 Performance at Distillation Unit #1500 PT. X. Based on the calculation, the Rd value and %heat efficiency for 5 days tend to fluctuate. The Rd value ranges from 0.00094832 btu/hr.ft2.ᵒF to 0.002121257 btu/hr.ft2 .ᵒF, while the heat efficiency value ranges from 48% to 51%. The HE evaluation results on the 31st have the highest Rd value of 0.00212157 btu/hr.ft2 .ᵒF) so that the resulting heat efficiency value is 50%. While the HE evaluation results on the 28th have the lowest Rd value of 0.00094832 (btu/hr.ft2.ᵒF) so that it has the highest efficiency of 51%. The overall head coefficient (Uc) value is greater than the design overall coefficient (Ud) which indicates that the heat transfer in a clean state is higher than in a dirty state, so it can be said that cooler #1533 is still in a state worth using. The ΔP value for the shell has a value of 0.086605283 Psi and the ΔP value on the tube is 0.007 Psi range. This value is still below the standard value allowed, which is 10 Psi.

Jurnal Mekanova Mekanikal Inovasi dan TeknologiVol. 11(1)
Openalex Percentile: Top 88%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluasi Kinerja Cooler #1533 Pada Unit Distilasi #1500 PT. X — Aulia Wahyuningtyas, Dinda Laras Ayu · Jurnal Mekanova Mekanikal Inovasi dan Teknologi (2025) | TGRS Research Map | TGRS