Wireless Suture Button Accessory Sensor for Intra- and Post-Operative Monitoring of Suture Loading in Soft Tissue Reconstruction

Background Tensioning and relaxation of grafts in tendon and ligament reconstruction surgeries significantly influence operation success, yet there are no clinically available technologies that can effectively measure both graft tension intra-operatively and during post-surgical recovery and rehabilitation. Objective To address the lack of an effective technology to measure graft tension intra-operatively and post-operatively, an implantable sensor was developed to provide real-time suture loading biofeedback both during reconstruction for surgeons and during rehabilitation exercises for physical therapists. Methods This paper introduces a passively powered wireless sensor designed to monitor tension of tendon and ligament sutures fixed in orthopedic reconstruction surgeries. The inductive-capacitive-resistive (LCR) based sensor was designed to be used along with commercially available suture buttons to monitor loading in reconstructed tendons and ligaments. Results Sensor loading experiments demonstrated a detection range from 5 N to 180 N with high repeatability (1.8 % change in sensitivity over 10,000 cycles). Additionally, the effects of depth, alignment, and orientation on signal transmission between the implantable sensor and an external detection device were characterized. Finally, the sensor was deployed in an anterior cruciate ligament reconstructed cadaver knee and used to detect graft loading during various knee joint movements. Conclusion This study established the design and basic functionality of a suture button accessory loading sensor to potentially assist orthopedic surgeons with surgical technique and help physical therapists with optimizing rehabilitation protocols for enhanced recovery in an effort to reduce failure rates.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Experience & Innovation
Published
2025-06-18
DOI
https://doi.org/10.60118/001c.128534
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wireless Suture Button Accessory Sensor for Intra- and Post-Operative Monitoring of Suture Loading in Soft Tissue Reconstruction

Michael McGeehan, Samuel Bruce Adams, Jonathan C. Riboh, Nicholas L. Strasser et al.
Journal of Orthopaedic Experience & Innovation
Knee injuries and reconstruction techniques
article

Wireless Suture Button Accessory Sensor for Intra- and Post-Operative Monitoring of Suture Loading in Soft Tissue Reconstruction

Michael McGeehan, Samuel Bruce Adams, Jonathan C. Riboh, Nicholas L. Strasser, Keat Ghee Ong, Kaylee Meyers, Robert E. Guldberg, Ken Gall, Salil Sidharthan Karipott, Stephen Laffoon
article en

Abstract

Background Tensioning and relaxation of grafts in tendon and ligament reconstruction surgeries significantly influence operation success, yet there are no clinically available technologies that can effectively measure both graft tension intra-operatively and during post-surgical recovery and rehabilitation. Objective To address the lack of an effective technology to measure graft tension intra-operatively and post-operatively, an implantable sensor was developed to provide real-time suture loading biofeedback both during reconstruction for surgeons and during rehabilitation exercises for physical therapists. Methods This paper introduces a passively powered wireless sensor designed to monitor tension of tendon and ligament sutures fixed in orthopedic reconstruction surgeries. The inductive-capacitive-resistive (LCR) based sensor was designed to be used along with commercially available suture buttons to monitor loading in reconstructed tendons and ligaments. Results Sensor loading experiments demonstrated a detection range from 5 N to 180 N with high repeatability (1.8 % change in sensitivity over 10,000 cycles). Additionally, the effects of depth, alignment, and orientation on signal transmission between the implantable sensor and an external detection device were characterized. Finally, the sensor was deployed in an anterior cruciate ligament reconstructed cadaver knee and used to detect graft loading during various knee joint movements. Conclusion This study established the design and basic functionality of a suture button accessory loading sensor to potentially assist orthopedic surgeons with surgical technique and help physical therapists with optimizing rehabilitation protocols for enhanced recovery in an effort to reduce failure rates.

Journal of Orthopaedic Experience & InnovationVol. 6(1)
Duke University (US), Vanderbilt University (US), Duke Medical Center (US), OrthoCarolina (US)
National Science Foundation, Directorate for STEM Education
Good health and well-being
Openalex Percentile: Top 76%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.