Quantitative Electroencephalographic Measures of Voltage Amplitude and Dominant Frequency Associated With the Stroop Color-Conflict Cognitive-Interference Task in Medical Students

Background Cognitive load theory postulates that effective learning depends on balancing a learner's cognitive capacity with cognitive load. Medical students are required to answer complex multiple-choice questions (MCQs) that involve complex vignettes and distractors, in 90 s per question. This demands the ability to rapidly process information, filter out irrelevant data, and suppress incorrect yet tempting answer choices. The Stroop color-conflict test represents a cognitive interference task that may simulate time-limited conditions for answering MCQs. This exploratory study tested whether selected quantitative electroencephalographic (qEEG) indices could behave as biomarkers that remain stable across sequential Stroop loads. Methods Thirteen healthy adults (11 retained after outlier removal) completed a midline (Fz, Cz, Pz) qEEG protocol comprising (i) 5 minutes of resting baseline, (ii) 5 minutes after a congruent low-load (LL) Stroop test and (iii) 5 minutes after an incongruent high-load (HL) Stroop test. Voltage amplitude (µV) and mode frequency (Hz) were extracted for theta (4-7 Hz), alpha (8-12 Hz), low-beta (12-20 Hz) and high-beta (20-30 Hz) bandwidths. Derived ratios, θ/β, α/β, θ/α and high-β/low-β, plus a frontal-posterior theta ratio (Fz/Pz), were analyzed with paired t-tests and repeated-measures ANOVA. Outliers were removed using a strict |z| > 2 threshold applied to every site-specific metric. Results Significant Baseline → LL load sensitivity was found for alpha-dominant (mode) frequency. The dominant frequencies, voltage amplitudes and voltage amplitude ratios for the other bandwidths (θ, low-β, high-β) were nonsignificant and therefore not load sensitive. None of the markers exhibited significant changes from LL → HL. Alpha voltage amplitudes were found to be higher at Pz than at Cz and Fz, exhibiting posterior dominant site sensitivity. High-β/low-β and θ/β ratios were found to be higher at Fz and Cz than at Pz, exhibiting frontal dominant site sensitivity. Conclusion These findings suggest significant Stroop testing-related qEEG changes in medical students trained to answer complex MCQs under time constraints. Alpha dominant frequency was found to be load sensitive but site insensitive. Load insensitivity of alpha voltage amplitude, θ/β ratio and high-β/low-β ratio at the Cz, Fz and Pz midline recording sites suggests site specificity of these variables. These findings appear to support the hypothesis that the site-specific topographic markers alpha voltage amplitude, θ/β and high-β/low-β ratio may be useful for characterizing responses to Stroop testing. However, the load sensitivity of alpha dominant frequency measured at the Cz, Fz and Pz midline recording sites may be useful for workload tracking to identify and remediate information-processing problems. These preliminary findings should be interpreted cautiously pending larger studies of cognitive loading in other populations of learners trained to take high-stakes, time-limited examinations.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-06-18
DOI
https://doi.org/10.7759/cureus.86277
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Electroencephalographic Measures of Voltage Amplitude and Dominant Frequency Associated With the Stroop Color-Conflict Cognitive-Interference Task in Medical Students

Richard M. Millis, Shweta Verma, Merin Chandanathil, David J. Crowley et al.
Cureus
EEG and Brain-Computer Interfaces
article

Quantitative Electroencephalographic Measures of Voltage Amplitude and Dominant Frequency Associated With the Stroop Color-Conflict Cognitive-Interference Task in Medical Students

Richard M. Millis, Shweta Verma, Merin Chandanathil, David J. Crowley, Nicole R Moldovan, Darine Alame, Brianna Easton, N'Kozi Bennett
article en

Abstract

Background Cognitive load theory postulates that effective learning depends on balancing a learner's cognitive capacity with cognitive load. Medical students are required to answer complex multiple-choice questions (MCQs) that involve complex vignettes and distractors, in 90 s per question. This demands the ability to rapidly process information, filter out irrelevant data, and suppress incorrect yet tempting answer choices. The Stroop color-conflict test represents a cognitive interference task that may simulate time-limited conditions for answering MCQs. This exploratory study tested whether selected quantitative electroencephalographic (qEEG) indices could behave as biomarkers that remain stable across sequential Stroop loads. Methods Thirteen healthy adults (11 retained after outlier removal) completed a midline (Fz, Cz, Pz) qEEG protocol comprising (i) 5 minutes of resting baseline, (ii) 5 minutes after a congruent low-load (LL) Stroop test and (iii) 5 minutes after an incongruent high-load (HL) Stroop test. Voltage amplitude (µV) and mode frequency (Hz) were extracted for theta (4-7 Hz), alpha (8-12 Hz), low-beta (12-20 Hz) and high-beta (20-30 Hz) bandwidths. Derived ratios, θ/β, α/β, θ/α and high-β/low-β, plus a frontal-posterior theta ratio (Fz/Pz), were analyzed with paired t-tests and repeated-measures ANOVA. Outliers were removed using a strict |z| > 2 threshold applied to every site-specific metric. Results Significant Baseline → LL load sensitivity was found for alpha-dominant (mode) frequency. The dominant frequencies, voltage amplitudes and voltage amplitude ratios for the other bandwidths (θ, low-β, high-β) were nonsignificant and therefore not load sensitive. None of the markers exhibited significant changes from LL → HL. Alpha voltage amplitudes were found to be higher at Pz than at Cz and Fz, exhibiting posterior dominant site sensitivity. High-β/low-β and θ/β ratios were found to be higher at Fz and Cz than at Pz, exhibiting frontal dominant site sensitivity. Conclusion These findings suggest significant Stroop testing-related qEEG changes in medical students trained to answer complex MCQs under time constraints. Alpha dominant frequency was found to be load sensitive but site insensitive. Load insensitivity of alpha voltage amplitude, θ/β ratio and high-β/low-β ratio at the Cz, Fz and Pz midline recording sites suggests site specificity of these variables. These findings appear to support the hypothesis that the site-specific topographic markers alpha voltage amplitude, θ/β and high-β/low-β ratio may be useful for characterizing responses to Stroop testing. However, the load sensitivity of alpha dominant frequency measured at the Cz, Fz and Pz midline recording sites may be useful for workload tracking to identify and remediate information-processing problems. These preliminary findings should be interpreted cautiously pending larger studies of cognitive loading in other populations of learners trained to take high-stakes, time-limited examinations.

CureusVol. 17(6)
Monmouth University (US), American University of Antigua (AG)
Openalex Percentile: Top 87%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.