Parametric Effects of Mixing Channel Geometry on Entrainment Characteristics of Ejector in R410A Heat Pump Systems

The two-phase ejector has gained prominence in heat pump systems as a device that effectively mitigates throttling losses through expansion work recovery. This investigation employs three-dimensional computational fluid dynamics (CFD) simulations to analyze the parametric effects of the mixing channel geometry on the entrainment characteristics in an R410A ejector. After validating the model according to the experimental data, the parameter analysis was carried out, and four key geometric parameters were changed within a certain range: the nozzle exit position (NXP = 13–19 mm), the pre-mixing channel convergent angle (CA = 20–60°), the diameter ratio (DDR = 5.0–7.1), and the length-to-diameter ratio (LDR = 8.9–12.4). Multi-variable optimization studies revealed optimal geometric configurations at NXP = 17 mm (about 3.5Dmix), CA = 30°, DR = 6.4, and LDR = 11.1, yielding an optimized mass entrainment ratio enhancement of 23.6% compared to baseline designs. This research provides actionable guidelines for the design of high-efficiency ejector components for heat pump applications.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-06-18
DOI
https://doi.org/10.3390/pr13061933
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parametric Effects of Mixing Channel Geometry on Entrainment Characteristics of Ejector in R410A Heat Pump Systems

Meiyuan Yang, Zhengdao Zhou, Yuying Wang, Li Yang et al.
1 citations
Processes
Refrigeration and Air Conditioning Technologies
0.71
article

Parametric Effects of Mixing Channel Geometry on Entrainment Characteristics of Ejector in R410A Heat Pump Systems

Meiyuan Yang, Zhengdao Zhou, Yuying Wang, Li Yang, Zhenying Zhang, Li Chang
article en
1 citations

Abstract

The two-phase ejector has gained prominence in heat pump systems as a device that effectively mitigates throttling losses through expansion work recovery. This investigation employs three-dimensional computational fluid dynamics (CFD) simulations to analyze the parametric effects of the mixing channel geometry on the entrainment characteristics in an R410A ejector. After validating the model according to the experimental data, the parameter analysis was carried out, and four key geometric parameters were changed within a certain range: the nozzle exit position (NXP = 13–19 mm), the pre-mixing channel convergent angle (CA = 20–60°), the diameter ratio (DDR = 5.0–7.1), and the length-to-diameter ratio (LDR = 8.9–12.4). Multi-variable optimization studies revealed optimal geometric configurations at NXP = 17 mm (about 3.5Dmix), CA = 30°, DR = 6.4, and LDR = 11.1, yielding an optimized mass entrainment ratio enhancement of 23.6% compared to baseline designs. This research provides actionable guidelines for the design of high-efficiency ejector components for heat pump applications.

ProcessesVol. 13(6)
North China University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 31%
Refrigeration and Air Conditioning Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.