Marginal adaptation of zirconia and porcelain fused to metal crowns fabricated by different CAD/CAM milling and lost-wax techniques: a comparative study

Objective. This in vitro study aimed to compare the marginal adaptation of monolithic zirconia crowns fabricated using two different CAD/CAM milling units (CORiTEC 150 and CERAMILL motion DRS) with porcelain-fused-to-metal (PFM) crowns produced using the conventional lost-wax technique. Methods. Thirty standardized resin models of an upper first molar were prepared and divided into three groups (n = 10 per group). Twenty zirconia crowns were milled using the CORiTEC 150 and CERAMILL motion DRS systems, while PFM crowns were fabricated using the lost-wax technique. All crowns were cemented, aged for 48 hours, and sectioned to measure marginal discrepancies at six points per specimen under 40× stereomicroscopy. Data were analyzed using independent t-tests and ANOVA followed by post hoc tests, with p < 0.05 considered statistically significant. Results. The CORiTEC 150 group demonstrated the lowest mean marginal discrepancy (55.83 ± 19.39 µm), followed by CERAMILL motion DRS (69.98 ± 20.38 µm), while PFM crowns showed the highest values (109.72 ± 42.47 µm). CAD/CAM-fabricated zirconia crowns exhibited significantly smaller marginal gaps than PFM crowns (p < 0.001). Post hoc analysis confirmed statistically significant differences between all pairwise comparisons (p < 0.05). Conclusions. All groups demonstrated marginal adaptation within clinically acceptable limits. CAD/CAM-fabricated zirconia crowns outperformed PFM crowns. Among the tested systems, CORiTEC 150 showed the best marginal adaptation. These findings suggest that CAD/CAM zirconia crowns, especially those produced by CORiTEC 150, may enhance long-term clinical success by reducing the risk of microleakage, secondary caries, and cement dissolution.

Authors

Publication Details

Journal
Romanian Journal of Stomatology
Published
2025-06-18
DOI
https://doi.org/10.37897/rjs.2025.2.7
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Marginal adaptation of zirconia and porcelain fused to metal crowns fabricated by different CAD/CAM milling and lost-wax techniques: a comparative study

Mohammed M. Al Moaleem, Ibrahim Zaid Al-Shami, Mohsen Ali Al-Hamzi, Abdullah Hashem Mohammed et al.
Romanian Journal of Stomatology
Dental materials and restorations
article

Marginal adaptation of zirconia and porcelain fused to metal crowns fabricated by different CAD/CAM milling and lost-wax techniques: a comparative study

Mohammed M. Al Moaleem, Ibrahim Zaid Al-Shami, Mohsen Ali Al-Hamzi, Abdullah Hashem Mohammed, Thanoon Abdo Baggash
article en

Abstract

Objective. This in vitro study aimed to compare the marginal adaptation of monolithic zirconia crowns fabricated using two different CAD/CAM milling units (CORiTEC 150 and CERAMILL motion DRS) with porcelain-fused-to-metal (PFM) crowns produced using the conventional lost-wax technique. Methods. Thirty standardized resin models of an upper first molar were prepared and divided into three groups (n = 10 per group). Twenty zirconia crowns were milled using the CORiTEC 150 and CERAMILL motion DRS systems, while PFM crowns were fabricated using the lost-wax technique. All crowns were cemented, aged for 48 hours, and sectioned to measure marginal discrepancies at six points per specimen under 40× stereomicroscopy. Data were analyzed using independent t-tests and ANOVA followed by post hoc tests, with p < 0.05 considered statistically significant. Results. The CORiTEC 150 group demonstrated the lowest mean marginal discrepancy (55.83 ± 19.39 µm), followed by CERAMILL motion DRS (69.98 ± 20.38 µm), while PFM crowns showed the highest values (109.72 ± 42.47 µm). CAD/CAM-fabricated zirconia crowns exhibited significantly smaller marginal gaps than PFM crowns (p < 0.001). Post hoc analysis confirmed statistically significant differences between all pairwise comparisons (p < 0.05). Conclusions. All groups demonstrated marginal adaptation within clinically acceptable limits. CAD/CAM-fabricated zirconia crowns outperformed PFM crowns. Among the tested systems, CORiTEC 150 showed the best marginal adaptation. These findings suggest that CAD/CAM zirconia crowns, especially those produced by CORiTEC 150, may enhance long-term clinical success by reducing the risk of microleakage, secondary caries, and cement dissolution.

Romanian Journal of StomatologyVol. 71(2)
Openalex Percentile: Top 85%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Marginal adaptation of zirconia and porcelain fused to metal crowns fabricated by different CAD/CAM milling and lost-wax techniques: a comparative study — Mohammed M. Al Moaleem, Ibrahim Zaid Al-Shami, et al. · Romanian Journal of Stomatology (2025) | TGRS Research Map | TGRS