Quantitative Measurement of Tau Burden in a Dual-Time-Window Dynamic PET Imaging Protocol with [<sup>18</sup>F]MK6240

This study aimed to test and validate a dual-time-window (DTW) protocol for 6-(fluoro-<sup>18</sup>F)-3-(<sup>1</sup>H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([<sup>18</sup>F]MK6240) dynamic PET imaging in experimental datasets acquired in human subjects. <b>Methods:</b> DTW protocols were tested and validated in datasets previously collected in 25 participants: 13 were cognitively normal, 10 had mild cognitive impairment, and 2 had Alzheimer disease. Participants underwent full 120-min [<sup>18</sup>F]MK6240 dynamic PET scans as well as structural MRI. Intermediary 3-dimensional volumes were removed from the acquired dynamic PET images to emulate DTW acquisitions consisting of an early phase and a late phase. Five break durations (30, 40, 50, 60, and 70 min) were investigated to determine the optimal break for 2 study durations (120 and 110 min). Regional brain time-activity curves were extracted using atlases available in the Montreal Neurologic Institute template space and using the FreeSurfer parcellation. Interpolation strategies were tested to recover the missing time points. Distribution volume ratio (DVR) estimates obtained from the DTW time-activity curves were compared with those obtained from the full time-activity curves as reference. Parametric maps were generated for the selected protocol and evaluated. <b>Results:</b> The correlation and agreement between DVR values obtained from the DTW method and the full time-activity curves were overall very good. The DTW protocol with a 60-min break using a biexponential model fit as the interpolation method provided the best compromise between practicality and quantitative accuracy. The mean differences between this DTW and the full acquisition, averaged across brain regions and all subjects, were less than 1% with a corresponding SD of less than 4%, and DVR estimates were not statistically different from those obtained from the full acquisition (<i>P</i> > 0.05). DVR parametric images were visually and quantitatively consistent with those obtained from the full acquisition. <b>Conclusion:</b> This study presents strong support for the use of a DTW protocol with [<sup>18</sup>F]MK6240. Such a protocol would be well suited to allow for both quantification of tau and derivation of an index of cerebral perfusion while reducing patient discomfort and increasing scanning efficiency in comparison to a full dynamic acquisition.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine
Published
2025-06-18
DOI
https://doi.org/10.2967/jnumed.125.270165
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Measurement of Tau Burden in a Dual-Time-Window Dynamic PET Imaging Protocol with [18F]MK6240

Rik Ossenkoppele, Keith A. Johnson, Nicolas J. Guehl, Maëva Dhaynaut et al.
1 citations
Journal of Nuclear Medicine
Medical Imaging Techniques and Applications
1.36
article

Quantitative Measurement of Tau Burden in a Dual-Time-Window Dynamic PET Imaging Protocol with [18F]MK6240

Rik Ossenkoppele, Keith A. Johnson, Nicolas J. Guehl, Maëva Dhaynaut, Bernard Hanseeuw, Georges El Fakhri, Cristina Lois, Yanis Chemli, Emma G. Thibault, Marc D. Normandin, Colin Groot, Ye Xia
article en
1 citations

Abstract

This study aimed to test and validate a dual-time-window (DTW) protocol for 6-(fluoro-<sup>18</sup>F)-3-(<sup>1</sup>H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([<sup>18</sup>F]MK6240) dynamic PET imaging in experimental datasets acquired in human subjects. <b>Methods:</b> DTW protocols were tested and validated in datasets previously collected in 25 participants: 13 were cognitively normal, 10 had mild cognitive impairment, and 2 had Alzheimer disease. Participants underwent full 120-min [<sup>18</sup>F]MK6240 dynamic PET scans as well as structural MRI. Intermediary 3-dimensional volumes were removed from the acquired dynamic PET images to emulate DTW acquisitions consisting of an early phase and a late phase. Five break durations (30, 40, 50, 60, and 70 min) were investigated to determine the optimal break for 2 study durations (120 and 110 min). Regional brain time-activity curves were extracted using atlases available in the Montreal Neurologic Institute template space and using the FreeSurfer parcellation. Interpolation strategies were tested to recover the missing time points. Distribution volume ratio (DVR) estimates obtained from the DTW time-activity curves were compared with those obtained from the full time-activity curves as reference. Parametric maps were generated for the selected protocol and evaluated. <b>Results:</b> The correlation and agreement between DVR values obtained from the DTW method and the full time-activity curves were overall very good. The DTW protocol with a 60-min break using a biexponential model fit as the interpolation method provided the best compromise between practicality and quantitative accuracy. The mean differences between this DTW and the full acquisition, averaged across brain regions and all subjects, were less than 1% with a corresponding SD of less than 4%, and DVR estimates were not statistically different from those obtained from the full acquisition (<i>P</i> > 0.05). DVR parametric images were visually and quantitatively consistent with those obtained from the full acquisition. <b>Conclusion:</b> This study presents strong support for the use of a DTW protocol with [<sup>18</sup>F]MK6240. Such a protocol would be well suited to allow for both quantification of tau and derivation of an index of cerebral perfusion while reducing patient discomfort and increasing scanning efficiency in comparison to a full dynamic acquisition.

Journal of Nuclear MedicineVol. 66(8)
Cliniques Universitaires Saint-Luc (BE), Harvard University (US), Lund University (SE), Yale University (US), Massachusetts General Hospital (US), UCLouvain (BE)
Openalex Percentile: Top 19%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.