Research on the Influence of Distributed Static Series Compensator on the Line Distance Relay Protection

As a series flexible control device, the distributed static series compensator (DSSC) can effectively and flexibly adjust the parameters of the power line, improving the stability of the new power system. In this paper, the topological structure of DSSC is analyzed, and the control method of DSSC device is derived. Subsequently, the influence of DSSC on distance relay is studied Through theoretical analysis, the impact of additional impedance generated by DSSC device operating in different compensation states on the measured impedance is obtained. Through simulation verification, it has been proven that the connection of DSSC has an undeniable impact on the ground impedance relay. The operation of DSSC in inductive compensation state will increase the risk of refusing action of relay protection device, while the operation of DSSC in capacitive compensation state may cause the relay protection device to malfunction and the larger the output voltage of DSSC, the more obvious the impact.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/ceepe64987.2025.11034065
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the Influence of Distributed Static Series Compensator on the Line Distance Relay Protection

Aihong Tang, Xuanchen Liu, Zihan Wang
Power Systems Fault Detection
article

Research on the Influence of Distributed Static Series Compensator on the Line Distance Relay Protection

Aihong Tang, Xuanchen Liu, Zihan Wang
article en

Abstract

As a series flexible control device, the distributed static series compensator (DSSC) can effectively and flexibly adjust the parameters of the power line, improving the stability of the new power system. In this paper, the topological structure of DSSC is analyzed, and the control method of DSSC device is derived. Subsequently, the influence of DSSC on distance relay is studied Through theoretical analysis, the impact of additional impedance generated by DSSC device operating in different compensation states on the measured impedance is obtained. Through simulation verification, it has been proven that the connection of DSSC has an undeniable impact on the ground impedance relay. The operation of DSSC in inductive compensation state will increase the risk of refusing action of relay protection device, while the operation of DSSC in capacitive compensation state may cause the relay protection device to malfunction and the larger the output voltage of DSSC, the more obvious the impact.

Wuhan University of Technology (CN)
Openalex Percentile: Top 84%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.