Research on Power Quality of Critical Loads of Single-phase Four-level Electric Spring

Aiming at the problems of the traditional Electric Spring (ES), which has a large harmonic content of the critical load voltage when the grid voltage fluctuates, as well as the low DC-side voltage utilization under the topology of the traditional H-bridge inverter, this paper proposes a topology structure of single-phase four-level ES, introduces the control strategy of ES based on this topology, and studies the modulation strategy of this topology. Based on this modulation strategy, four working principles of the topology are analyzed, Fourier series of inverter output voltage of the single-phase four-level Electric Spring is derived, and DC side voltage utilization rate is calculated, indicating that the DC side voltage utilization rate is increased by 42.5%. Finally, simulation results with MATLAB/Simulink show: Under the same control strategy, compared with the traditional ES-2, the Total Harmonic Distortion (THD) of the critical load voltage of the Single-phase Four-level Electric Spring decreases by 0.12% when the electrical grid voltage fluctuates. The effectiveness of Single-phase Four-level Electric Spring for improving power quality of critical loads is verified.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/ceepe64987.2025.11034037
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Power Quality of Critical Loads of Single-phase Four-level Electric Spring

Mi Zhou, Chaohui Zhao, Xiaohu Wang, Zhun Huang
High-Voltage Power Transmission Systems
article

Research on Power Quality of Critical Loads of Single-phase Four-level Electric Spring

Mi Zhou, Chaohui Zhao, Xiaohu Wang, Zhun Huang
article en

Abstract

Aiming at the problems of the traditional Electric Spring (ES), which has a large harmonic content of the critical load voltage when the grid voltage fluctuates, as well as the low DC-side voltage utilization under the topology of the traditional H-bridge inverter, this paper proposes a topology structure of single-phase four-level ES, introduces the control strategy of ES based on this topology, and studies the modulation strategy of this topology. Based on this modulation strategy, four working principles of the topology are analyzed, Fourier series of inverter output voltage of the single-phase four-level Electric Spring is derived, and DC side voltage utilization rate is calculated, indicating that the DC side voltage utilization rate is increased by 42.5%. Finally, simulation results with MATLAB/Simulink show: Under the same control strategy, compared with the traditional ES-2, the Total Harmonic Distortion (THD) of the critical load voltage of the Single-phase Four-level Electric Spring decreases by 0.12% when the electrical grid voltage fluctuates. The effectiveness of Single-phase Four-level Electric Spring for improving power quality of critical loads is verified.

Shanghai University of Electric Power (CN), Shanghai Dianji University (CN)
Affordable and clean energy
Openalex Percentile: Top 88%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Power Quality of Critical Loads of Single-phase Four-level Electric Spring — Mi Zhou, Chaohui Zhao, et al. · (2025) | TGRS Research Map | TGRS