Simulation on the Epoxy Resin Impregnated Paper Bushings Performance of Different Voltage Levels

Epoxy resin impregnated paper bushings, as key components in power systems, are subjected to multiple physical fields such as electricity, heat, and force over the long term. Their performance stability is crucial for the safe operation of transformers. This paper introduces the structure of new types of epoxy resin impregnated paper bushings with rated voltages of 36kV and 72.5kV. The paper simulates the electric field distribution of different bushings under operating conditions using the finite element simulation method and calculates their seismic resistance. The simulation results show that the working electric field strength varies according to the different structural characteristics of the products. With the increase of the rated voltage, the maximum field strength on the core surface increases from 2.11kV/mm to 2.18kV/mm. Both types of bushings can withstand an earthquake intensity of 8 degrees. The performance of the two types of transformer bushings introduced in this paper meets the requirements for normal use.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/ceepe64987.2025.11033842
Primary Topic
Material Properties and Processing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation on the Epoxy Resin Impregnated Paper Bushings Performance of Different Voltage Levels

Tianming Yan, Libao Liu, Wenkai Tang, Zhijun Luo et al.
Material Properties and Processing
article

Simulation on the Epoxy Resin Impregnated Paper Bushings Performance of Different Voltage Levels

Tianming Yan, Libao Liu, Wenkai Tang, Zhijun Luo, Daijun Liu, Liming Wang, Xiaoying Dong, Xin Tong
article en

Abstract

Epoxy resin impregnated paper bushings, as key components in power systems, are subjected to multiple physical fields such as electricity, heat, and force over the long term. Their performance stability is crucial for the safe operation of transformers. This paper introduces the structure of new types of epoxy resin impregnated paper bushings with rated voltages of 36kV and 72.5kV. The paper simulates the electric field distribution of different bushings under operating conditions using the finite element simulation method and calculates their seismic resistance. The simulation results show that the working electric field strength varies according to the different structural characteristics of the products. With the increase of the rated voltage, the maximum field strength on the core surface increases from 2.11kV/mm to 2.18kV/mm. Both types of bushings can withstand an earthquake intensity of 8 degrees. The performance of the two types of transformer bushings introduced in this paper meets the requirements for normal use.

Tsinghua University (CN)
Openalex Percentile: Top 84%
Material Properties and Processing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.