Output Response Characteristics of Multiple Parallel Inverters under Weak Grid Conditions

Under weak grid conditions, the grid impedance causes the point of common coupling (PCC) voltage to become non-constant. As a result, the output current of the inverter is influenced by grid voltage fluctuation while simultaneously affecting the PCC voltage. In order to quantitatively analyze the output response characteristics and interaction mechanism of multiple parallel inverter nodes, this paper investigates the L-type three-phase grid-connected inverter based on the vector control strategy of grid-voltage-oriented and the dual-loop control strategy of voltage and current. By analyzing the system model and dynamic equations of the grid-connected inverter, the transfer function of the single-inverter closed-loop system is derived. The interaction mechanism of multiple parallel grid-connected inverters is analyzed based on the transfer function of a single-inverter system. Finally, the three-phase grid-connected inverter model was developed in Matlab/Simulink. The effectiveness of the derived transfer function and interaction mechanism was verified through a case study, and the output response characteristics of the multi-parallel inverter nodes were quantitatively analyzed.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/ceepe64987.2025.11034084
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Output Response Characteristics of Multiple Parallel Inverters under Weak Grid Conditions

Guiqiang Ding, Shuxian Fan, Min Song, Yuanqi Wang et al.
Microgrid Control and Optimization
article

Output Response Characteristics of Multiple Parallel Inverters under Weak Grid Conditions

Guiqiang Ding, Shuxian Fan, Min Song, Yuanqi Wang, Hengxu Ha, Yanyu Ma
article en

Abstract

Under weak grid conditions, the grid impedance causes the point of common coupling (PCC) voltage to become non-constant. As a result, the output current of the inverter is influenced by grid voltage fluctuation while simultaneously affecting the PCC voltage. In order to quantitatively analyze the output response characteristics and interaction mechanism of multiple parallel inverter nodes, this paper investigates the L-type three-phase grid-connected inverter based on the vector control strategy of grid-voltage-oriented and the dual-loop control strategy of voltage and current. By analyzing the system model and dynamic equations of the grid-connected inverter, the transfer function of the single-inverter closed-loop system is derived. The interaction mechanism of multiple parallel grid-connected inverters is analyzed based on the transfer function of a single-inverter system. Finally, the three-phase grid-connected inverter model was developed in Matlab/Simulink. The effectiveness of the derived transfer function and interaction mechanism was verified through a case study, and the output response characteristics of the multi-parallel inverter nodes were quantitatively analyzed.

Shandong University (CN), China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Output Response Characteristics of Multiple Parallel Inverters under Weak Grid Conditions — Guiqiang Ding, Shuxian Fan, et al. · (2025) | TGRS Research Map | TGRS