Research on Broadband Transfer Characteristics of Capacitive Voltage Transformer and Its Influencing Factors

Based on the basic structure of 110kV ${\text{TYD}}110\sqrt 3 0.02{\text{H}}$ type capacitive voltage transformer, a physical equivalent circuit model is constructed, the harmonic transmission characteristics of CVT are analyzed, and the influence of component equivalent parameters and distribution parameters on the amplitude and frequency response curves is given. Research shows that due to the influence of CVT distribution parameters, there are singular points in its amplitude and phase frequency transmission characteristic curves. By adjusting the equivalent resistance, inductance and distributed capacitance parameters of the compensation reactor and intermediate transformer, the frequency of the singular points appear can be effectively changed, thereby greatly improving the wide-frequency harmonic response characteristics and harmonic measurement accuracy of the CVT.

Authors

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1109/eeice65049.2025.11034316
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Broadband Transfer Characteristics of Capacitive Voltage Transformer and Its Influencing Factors

Qingchan Liu, Zhaolei He, Cong Lin, Yujun Yin et al.
Power Systems Fault Detection
article

Research on Broadband Transfer Characteristics of Capacitive Voltage Transformer and Its Influencing Factors

Qingchan Liu, Zhaolei He, Cong Lin, Yujun Yin, Tengbin Li
article en

Abstract

Based on the basic structure of 110kV ${\text{TYD}}110\sqrt 3 0.02{\text{H}}$ type capacitive voltage transformer, a physical equivalent circuit model is constructed, the harmonic transmission characteristics of CVT are analyzed, and the influence of component equivalent parameters and distribution parameters on the amplitude and frequency response curves is given. Research shows that due to the influence of CVT distribution parameters, there are singular points in its amplitude and phase frequency transmission characteristic curves. By adjusting the equivalent resistance, inductance and distributed capacitance parameters of the compensation reactor and intermediate transformer, the frequency of the singular points appear can be effectively changed, thereby greatly improving the wide-frequency harmonic response characteristics and harmonic measurement accuracy of the CVT.

China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 84%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.