Optimization and Application on Reclosure of Line-line Strings with 3/2 Connection Mode in 220kV System

The reclosure of line-line strings with 3/2 connection mode in 220kV system is normally just set as single-pole reclosure. If one of the lines in the same string is transmission line of electrified railway Traction Substation, whose reclosure of side circuit breaker is set as three-pole reclosure. Power supply realiability of correspongding line will be greatly reduced on account of the reclosure difference when any side circuit breaker is in maintenance. Herein above statement, the risk of current reclosure mode is analysed firstly, and then different optimization schemes are put forward to eliminate the risk. Finally, the most optimal scheme is determined by comparison between different schemes to ensure power supply reliability.

Authors

Institutions

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/ceepe64987.2025.11033855
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization and Application on Reclosure of Line-line Strings with 3/2 Connection Mode in 220kV System

Yuanhang Yang, Qian Cheng, Hengchu Shi, Jing Chen et al.
Power Systems and Technologies
article

Optimization and Application on Reclosure of Line-line Strings with 3/2 Connection Mode in 220kV System

Yuanhang Yang, Qian Cheng, Hengchu Shi, Jing Chen, Hualiang Xiao, Hao You, Zhiyao Duan
article en

Abstract

The reclosure of line-line strings with 3/2 connection mode in 220kV system is normally just set as single-pole reclosure. If one of the lines in the same string is transmission line of electrified railway Traction Substation, whose reclosure of side circuit breaker is set as three-pole reclosure. Power supply realiability of correspongding line will be greatly reduced on account of the reclosure difference when any side circuit breaker is in maintenance. Herein above statement, the risk of current reclosure mode is analysed firstly, and then different optimization schemes are put forward to eliminate the risk. Finally, the most optimal scheme is determined by comparison between different schemes to ensure power supply reliability.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 88%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.