Analysis of Induced Voltage of UHV DC Ground Wire Under Ice Melting Working

In recent years, with the impact of severe ice disasters, there has been a significant demand for ground wire defrosting on UHV DC lines. While the lines are on live, the induced voltage of the ground wire has an impact on the defrosting device. This article takes the segmented ice melting of the ground wire of the Binjin line as an example, carries out simulation and measurements of induced voltage under different wiring methods of the ground wire during ice melting work. The results show that when both ends of the ground wire in the ice melting section are connected and ungrounded, the maximum induced voltage can reach 78kV; When one end of the two ground wires is connected and the other end is open, the maximum induced voltage can reach 50kV; When the ground wire is connected and grounded, the induced voltage at both ends approaches zero. The simulation results have good consistency with the measured data, providing support for the safe implementation of ground wire ice melting in UHV DC lines.

Authors

Publication Details

Published
2025-04-25
DOI
https://doi.org/10.1109/ceepe64987.2025.11033822
Primary Topic
Icing and De-icing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Induced Voltage of UHV DC Ground Wire Under Ice Melting Working

Xinglie Lei, Jiakai Liang, Kai Zhu, Feng Lin et al.
4 links
Icing and De-icing Technologies
article

Analysis of Induced Voltage of UHV DC Ground Wire Under Ice Melting Working

Xinglie Lei, Jiakai Liang, Kai Zhu, Feng Lin, Junjie Zhao
article en

Abstract

In recent years, with the impact of severe ice disasters, there has been a significant demand for ground wire defrosting on UHV DC lines. While the lines are on live, the induced voltage of the ground wire has an impact on the defrosting device. This article takes the segmented ice melting of the ground wire of the Binjin line as an example, carries out simulation and measurements of induced voltage under different wiring methods of the ground wire during ice melting work. The results show that when both ends of the ground wire in the ice melting section are connected and ungrounded, the maximum induced voltage can reach 78kV; When one end of the two ground wires is connected and the other end is open, the maximum induced voltage can reach 50kV; When the ground wire is connected and grounded, the induced voltage at both ends approaches zero. The simulation results have good consistency with the measured data, providing support for the safe implementation of ground wire ice melting in UHV DC lines.

Openalex Percentile: Top 82%
Icing and De-icing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.