Non-contact Vital Sign Detection via MSO-VMD

The radio frequency-based non-contact monitoring method provides a feasible direction for reducing the burden on users and achieving stable health monitoring. Since the chest micro-movement caused by heartbeat and breathing is usually at the millimeter level, this paper uses 77Ghz FMCW millimeter-wave radar to implement vital sign monitoring. Variational mode decomposition (VMD) is used to decompose the breathing, heartbeat information and environmental clutter of the human echo signal. However, the selection of modal decomposition-related parameters will affect the effect of signal decomposition. To this end, this paper proposes a VMD algorithm based on MSO optimization. Simulation experiments illustrate the noise robustness and applicability of MSO-VMD in complex scenarios. In addition, the human echo pulse is obtained and processed in a real environment, and the accuracy of the algorithm is verified by the results of the contact device.

Authors

Institutions

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1109/eeice65049.2025.11034319
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-contact Vital Sign Detection via MSO-VMD

Jun Tang, Jiahui Cheng, Jie Wang, Jun Li
Retinal Imaging and Analysis
article

Non-contact Vital Sign Detection via MSO-VMD

Jun Tang, Jiahui Cheng, Jie Wang, Jun Li
article en

Abstract

The radio frequency-based non-contact monitoring method provides a feasible direction for reducing the burden on users and achieving stable health monitoring. Since the chest micro-movement caused by heartbeat and breathing is usually at the millimeter level, this paper uses 77Ghz FMCW millimeter-wave radar to implement vital sign monitoring. Variational mode decomposition (VMD) is used to decompose the breathing, heartbeat information and environmental clutter of the human echo signal. However, the selection of modal decomposition-related parameters will affect the effect of signal decomposition. To this end, this paper proposes a VMD algorithm based on MSO optimization. Simulation experiments illustrate the noise robustness and applicability of MSO-VMD in complex scenarios. In addition, the human echo pulse is obtained and processed in a real environment, and the accuracy of the algorithm is verified by the results of the contact device.

Xiamen University of Technology (CN)
Openalex Percentile: Top 79%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.