Multidimensional Information Fusion Learning for Real-time Signal Denoising in Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is a novel molecular imaging technique that enables highly sensitive visualization of the distribution of magnetic nanoparticles within biological tissues. However, dynamic random noises contained in MPI signal leads to artifacts. A common approach to improve signal-to-noise ratio (SNR) is averaging signals from multiple repeated measurements, significantly reducing real-time performance. To address this, we propose a deep learning method to remove random noise from short-time measurement signals, making them close to long-time measurement signals, thereby shortening the measurement time. We integrate the frequency indexes and coil channels of frequency components using a Transformer architecture, embedding it into the frequency domain signal to form multidimensional information. Subsequently, we introduce the row energy normalization method for signal preprocessing in model training. This approach makes the energy of the frequency components consistent, enhancing image reconstruction quality. Experiments on real-world datasets, including the OpenMPI dataset, the phantom dataset, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">in vivo</i> dataset, demonstrate our method can significantly eliminate random noise, improve the SNR of limited measurement signals, and obtain high-quality reconstructed images. This method can significantly improve the SNR on the phantom dataset from -24.1417 dB to 1.0184 dB, while shortening the acquisition time by 92.92%. Our method shortens acquisition time while ensuring imaging quality and robustness, enhancing the real-time imaging performance of MPI and providing a new approach for its biomedical applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3580831
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multidimensional Information Fusion Learning for Real-time Signal Denoising in Magnetic Particle Imaging

Zhongwei Bian, Lin Yin, Jie Tian, Yu An et al.
1 links
IEEE Transactions on Instrumentation and Measurement
Characterization and Applications of Magnetic Nanoparticles
article

Multidimensional Information Fusion Learning for Real-time Signal Denoising in Magnetic Particle Imaging

Zhongwei Bian, Lin Yin, Jie Tian, Yu An, Y.P. Guo, Xiaopeng Ma, Qian Liang, Jiaxuan Wen, Lixian Su, Zewen Sun, Yang Du
article en

Abstract

Magnetic Particle Imaging (MPI) is a novel molecular imaging technique that enables highly sensitive visualization of the distribution of magnetic nanoparticles within biological tissues. However, dynamic random noises contained in MPI signal leads to artifacts. A common approach to improve signal-to-noise ratio (SNR) is averaging signals from multiple repeated measurements, significantly reducing real-time performance. To address this, we propose a deep learning method to remove random noise from short-time measurement signals, making them close to long-time measurement signals, thereby shortening the measurement time. We integrate the frequency indexes and coil channels of frequency components using a Transformer architecture, embedding it into the frequency domain signal to form multidimensional information. Subsequently, we introduce the row energy normalization method for signal preprocessing in model training. This approach makes the energy of the frequency components consistent, enhancing image reconstruction quality. Experiments on real-world datasets, including the OpenMPI dataset, the phantom dataset, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">in vivo</i> dataset, demonstrate our method can significantly eliminate random noise, improve the SNR of limited measurement signals, and obtain high-quality reconstructed images. This method can significantly improve the SNR on the phantom dataset from -24.1417 dB to 1.0184 dB, while shortening the acquisition time by 92.92%. Our method shortens acquisition time while ensuring imaging quality and robustness, enhancing the real-time imaging performance of MPI and providing a new approach for its biomedical applications.

IEEE Transactions on Instrumentation and Measurement
Shandong University (CN), Chinese Academy of Sciences (CN), Shandong Institute of Automation (CN), Huazhong University of Science and Technology Hospital (CN), Hangzhou City University, Huazhong University of Science and Technology (CN), Beihang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 87%
Characterization and Applications of Magnetic Nanoparticles
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.