An Active Quasi-Circulator Technique for MHz Impedance Measurement for Wearables

A unique circuit technique utilizing the active quasi-circulator (AQC) for impedance measurement is presented. Overcoming limitations of size, frequency, and sensitivity, the technique enables sensitive MHz impedance measurements for wearable applications. The AQC measures the impedance of the device-under-test (DUT) at MHz excitation frequencies through nulling the output at the DUT match point while offering enhanced sensitivity. A circuit analysis presents the theory of operation and models the AQC to extract the DUT impedance. Fabricated in a 180-nm CMOS process, the circuit occupies an active area of 0.012 mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and demonstrates impedance measurement at excitation frequencies up to 25 MHz. The proposed circuit is attractive for measuring living tissues that exhibit strong bioimpedance response at MHz frequencies.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3580838
Primary Topic
Magneto-Optical Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Active Quasi-Circulator Technique for MHz Impedance Measurement for Wearables

Marcus Julian, Shiuh-Hua Wood Chiang, N. Allen, Robert C. Davis et al.
IEEE Transactions on Instrumentation and Measurement
Magneto-Optical Properties and Applications
article

An Active Quasi-Circulator Technique for MHz Impedance Measurement for Wearables

Marcus Julian, Shiuh-Hua Wood Chiang, N. Allen, Robert C. Davis, Sharisse Poff, Daniel H. Tebbs
article en

Abstract

A unique circuit technique utilizing the active quasi-circulator (AQC) for impedance measurement is presented. Overcoming limitations of size, frequency, and sensitivity, the technique enables sensitive MHz impedance measurements for wearable applications. The AQC measures the impedance of the device-under-test (DUT) at MHz excitation frequencies through nulling the output at the DUT match point while offering enhanced sensitivity. A circuit analysis presents the theory of operation and models the AQC to extract the DUT impedance. Fabricated in a 180-nm CMOS process, the circuit occupies an active area of 0.012 mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> and demonstrates impedance measurement at excitation frequencies up to 25 MHz. The proposed circuit is attractive for measuring living tissues that exhibit strong bioimpedance response at MHz frequencies.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Brigham Young University (US), Leavitt Partners (United States) (US), UConn Health (US)
Affordable and clean energy
Openalex Percentile: Top 88%
Magneto-Optical Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.