EXPRESS-LAAO Protocol With the New WATCHMAN FLX Pro Device

This study evaluates the procedural outcomes and short-term follow-up of the WATCHMAN FLX Pro left atrial appendage occlusion (LAAO) device (Boston Scientific) using the EXPRESS-LAAO protocol at a high-volume center. The new device offers enhanced features, including a 40-mm size for large anatomies, additional radiopaque markers for improved positioning, and a hemocompatible coating for faster endothelization. The EXPRESS-LAAO protocol streamlines patient management with pre-procedure computed tomography or cardiac magnetic resonance imaging, intracardiac echocardiography guidance, conscious sedation, and same-day discharge for stable patients. Between June and September 2024, 109 patients (median age 78 years, 48.6% female) underwent LAAO with the WATCHMAN FLX Pro device. Key indications included recurrent falls (33%), gastrointestinal bleeding (29.4%), and very high bleeding risk (21.1%). Procedural success was high (99.1%), with 1 case of cardiac tamponade requiring pericardiocentesis and no in-hospital complications. The 40-mm device was used in 7.3% of cases, proving essential for larger anatomies. At an average follow-up of 49.7 days, there was 1 lacunar stroke without device-related complications and 1 minor bleeding event. The study demonstrates the safety and effectiveness of the WATCHMAN FLX Pro device using the EXPRESS-LAAO protocol. The TruSteer catheter (Boston Scientific) facilitated implantations in complex anatomies, reducing the number of maneuvers. While post-LAAO imaging surveillance was a limitation, this is the first study assessing peri-procedural outcomes with the new device. Findings support its clinical utility in high-risk patients requiring LAAO.

Authors

Institutions

Publication Details

Journal
˜The œJournal of invasive cardiology/˜The œjournal of invasive cardiology
Published
2025-01-01
DOI
https://doi.org/10.25270/jic/25.00081
Primary Topic
Inertial Sensor and Navigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPRESS-LAAO Protocol With the New WATCHMAN FLX Pro Device

Anene Ukaigwe, Marco Frazzetto, Alexander Cove, Steven J. Filby et al.
˜The œJournal of invasive cardiology/˜The œjournal of invasive cardiology
Inertial Sensor and Navigation
article

EXPRESS-LAAO Protocol With the New WATCHMAN FLX Pro Device

Anene Ukaigwe, Marco Frazzetto, Alexander Cove, Steven J. Filby, Guilherme Ferragut Attizzani, Julia Tirelli, Rafey Feroze, Luís Augusto Palma Dallan, Nawaf Alhabdan, Yusef Saeed, Pedro Soares Texeira, Philippe Taieb
article en

Abstract

This study evaluates the procedural outcomes and short-term follow-up of the WATCHMAN FLX Pro left atrial appendage occlusion (LAAO) device (Boston Scientific) using the EXPRESS-LAAO protocol at a high-volume center. The new device offers enhanced features, including a 40-mm size for large anatomies, additional radiopaque markers for improved positioning, and a hemocompatible coating for faster endothelization. The EXPRESS-LAAO protocol streamlines patient management with pre-procedure computed tomography or cardiac magnetic resonance imaging, intracardiac echocardiography guidance, conscious sedation, and same-day discharge for stable patients. Between June and September 2024, 109 patients (median age 78 years, 48.6% female) underwent LAAO with the WATCHMAN FLX Pro device. Key indications included recurrent falls (33%), gastrointestinal bleeding (29.4%), and very high bleeding risk (21.1%). Procedural success was high (99.1%), with 1 case of cardiac tamponade requiring pericardiocentesis and no in-hospital complications. The 40-mm device was used in 7.3% of cases, proving essential for larger anatomies. At an average follow-up of 49.7 days, there was 1 lacunar stroke without device-related complications and 1 minor bleeding event. The study demonstrates the safety and effectiveness of the WATCHMAN FLX Pro device using the EXPRESS-LAAO protocol. The TruSteer catheter (Boston Scientific) facilitated implantations in complex anatomies, reducing the number of maneuvers. While post-LAAO imaging surveillance was a limitation, this is the first study assessing peri-procedural outcomes with the new device. Findings support its clinical utility in high-risk patients requiring LAAO.

˜The œJournal of invasive cardiology/˜The œjournal of invasive cardiologyVol. 37(11)
University Hospitals of Cleveland (US), University Hospitals Cleveland Medical Center (US)
Openalex Percentile: Top 82%
Inertial Sensor and Navigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.