Sand-coated hybrid FRP tubes for marine applications: Bond performance with seawater-sea sand concrete under seawater

• Bonds-slip behaviour between sand coated hybrid FRP tube and SWSSC exposed to seawater. • Bond failure modes of sand coated hybrid FRP tube and SWSSC after exposure to seawater. • Long-term bond strength prediction of sand coated hybrid FRP tube and SWSSC after exposure to seawater. This study investigates the durability of the bond between sand-coated hybrid carbon-glass fibre-reinforced polymer (HFRP) tubes and seawater-sea sand concrete (SWSSC) under simulated marine conditions. Concrete-filled filament-wound HFRP tubes were immersed in seawater at temperatures of 25 °C, 40 °C, and 60 °C for durations of 30, 90, and 120 days. Push-out tests were conducted to evaluate the bond performance of the concrete-filled FRP tubes (CFFTs), focusing on failure modes, bond strength, and bond-slip characteristics. Results revealed an initial enhancement in bond strength for all conditioned samples after 30 days compared to unconditioned references, followed by a gradual decline, culminating in a maximum bond strength reduction of 9 % after 120 days. The primary failure mode for conditioned specimens occurred at the interface between the HFRP tube and the sand-coated layer, while unconditioned specimens failed at the interface of the tube and the concrete. The study found that post-peak bond behaviour varied, with bond strength either maintained or gradually reduced, mainly due to the loss of chemical adhesion and friction. Using the fib Bulletin 40 approach, a knock-down factor of 0.5 is recommended for bond strength durability over a 50-year service life in seawater environments. This research stresses the potential of sand-coated HFRP tubes and SWSSC as sustainable, marine-compatible construction materials that meet structural durability requirements.

Authors

Institutions

Publication Details

Journal
Marine Structures
Published
2025-06-18
DOI
https://doi.org/10.1016/j.marstruc.2025.103872
Citations
6
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
6.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sand-coated hybrid FRP tubes for marine applications: Bond performance with seawater-sea sand concrete under seawater

Ali Rajabipour, Mehrdad Arashpour, Ali Hassanli, Milad Bazli et al.
6 citations
Marine Structures
Structural Behavior of Reinforced Concrete
6.04
article

Sand-coated hybrid FRP tubes for marine applications: Bond performance with seawater-sea sand concrete under seawater

Ali Rajabipour, Mehrdad Arashpour, Ali Hassanli, Milad Bazli, Jivan Subedi, Shalik Dhungana
article en
6 citations

Abstract

• Bonds-slip behaviour between sand coated hybrid FRP tube and SWSSC exposed to seawater. • Bond failure modes of sand coated hybrid FRP tube and SWSSC after exposure to seawater. • Long-term bond strength prediction of sand coated hybrid FRP tube and SWSSC after exposure to seawater. This study investigates the durability of the bond between sand-coated hybrid carbon-glass fibre-reinforced polymer (HFRP) tubes and seawater-sea sand concrete (SWSSC) under simulated marine conditions. Concrete-filled filament-wound HFRP tubes were immersed in seawater at temperatures of 25 °C, 40 °C, and 60 °C for durations of 30, 90, and 120 days. Push-out tests were conducted to evaluate the bond performance of the concrete-filled FRP tubes (CFFTs), focusing on failure modes, bond strength, and bond-slip characteristics. Results revealed an initial enhancement in bond strength for all conditioned samples after 30 days compared to unconditioned references, followed by a gradual decline, culminating in a maximum bond strength reduction of 9 % after 120 days. The primary failure mode for conditioned specimens occurred at the interface between the HFRP tube and the sand-coated layer, while unconditioned specimens failed at the interface of the tube and the concrete. The study found that post-peak bond behaviour varied, with bond strength either maintained or gradually reduced, mainly due to the loss of chemical adhesion and friction. Using the fib Bulletin 40 approach, a knock-down factor of 0.5 is recommended for bond strength durability over a 50-year service life in seawater environments. This research stresses the potential of sand-coated HFRP tubes and SWSSC as sustainable, marine-compatible construction materials that meet structural durability requirements.

Marine StructuresVol. 104
The University of Queensland (AU), University of South Australia (AU), Charles Darwin University (AU), Monash University (AU)
Life below water
Openalex Percentile: Top 4%
Structural Behavior of Reinforced Concrete
6.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.