Research on the influence of installation error of capacitive angle sensor on angle error

This paper discusses the effect of mechanical installation errors on the c results of capacitive angle sensor by COMSOL Multiphysics software; the angle was calculated using sines and cosines with capacitance value of the capacitive angle sensor. First, based on the principle of the sensor structure, the formula is derived which is petal-shaped in polar coordinates, and set the electrical parameters and rotation angles to realize the model simulation. Secondly, due to the installation errors which are easy to occur in real life, the simulation results are obtained by tilting and moving the model body to imitating the installation error in different cases. Finally, the results of installation errors in different initial situations are further analyzed and compared, including different tilt angles and horizontal movement distances respectively, and summarizing the impact of different installation errors on the measurement results.

Authors

Institutions

Publication Details

Journal
IEICE Electronics Express
Published
2025-06-18
DOI
https://doi.org/10.1587/elex.22.20250199
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the influence of installation error of capacitive angle sensor on angle error

Zhen Meng, Jianwen Wu, Liu Mou, Ang Ma et al.
IEICE Electronics Express
Advanced Measurement and Metrology Techniques
article

Research on the influence of installation error of capacitive angle sensor on angle error

Zhen Meng, Jianwen Wu, Liu Mou, Ang Ma, Xingcheng Zhang, Wei Mi, Yuepeng Yan
article en

Abstract

This paper discusses the effect of mechanical installation errors on the c results of capacitive angle sensor by COMSOL Multiphysics software; the angle was calculated using sines and cosines with capacitance value of the capacitive angle sensor. First, based on the principle of the sensor structure, the formula is derived which is petal-shaped in polar coordinates, and set the electrical parameters and rotation angles to realize the model simulation. Secondly, due to the installation errors which are easy to occur in real life, the simulation results are obtained by tilting and moving the model body to imitating the installation error in different cases. Finally, the results of installation errors in different initial situations are further analyzed and compared, including different tilt angles and horizontal movement distances respectively, and summarizing the impact of different installation errors on the measurement results.

IEICE Electronics ExpressVol. 22(15)
Tianjin University of Technology (CN), Chinese Academy of Sciences (CN), University of Chinese Academy of Sciences (CN)
Tianjin University of Technology, Tianjin University
Openalex Percentile: Top 86%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.