Automatic contour quality assurance using deep-learning based contours
<i>Objective.</i>Safe deployment of auto-contouring models requires the inclusion of automated quality assurance (QA). One such approach is to use two independent auto-contouring models and compare them geometrically for acceptability. This is not effective because geometric differences may not correlate with clinically significant errors. Herein, we investigated whether a two-contour QA system is improved by including dose in this comparison.<i>Approach.</i>Volumetric modulated arc therapy plans were generated for 86 head and neck (H&N) and 50 cervical (GYN) cancer patients, using clinically-approved planning target volumes (PTVs) and auto-contour organs-at-risk (OARs) from a primary auto-contouring model. Doses to the primary OARs were compared with doses to manually drawn and approved OARs ('the truth'). A difference in<i>D</i><sub>mean</sub>or<i>D</i><sub>max</sub>⩾ 2 Gy was identified as a reporting error (<i>D</i><sub>error</sub>). A second, independent auto-contouring model was then used to contour the OARs (verification). The primary and verification auto-contouring models were compared geometrically (dice similarity coefficient (DSC), surface DSC, 95% Hausdorff distance, mean surface distance) and dosimetrically (<i>D</i><sub>mean</sub>,<i>D</i><sub>max</sub>). The ability of comparison metrics between the two auto-contouring models to flag actual dosimetric errors (i.e. primary model compared with the truth) was investigated. A logistic regression model was used to predict<i>D</i><sub>error</sub>. The data was divided by disease site and into 50/50 stratified training and testing sets;<i>k</i>-fold cross validation was employed during training to avoid overfitting. H&N structures were further divided into size-specific groups to improve model performance and generalizability.<i>Main results.</i>Including dose metrics in the logistic regression model to predict<i>D</i><sub>error, mean</sub>increased the performance in terms of receiver-operating characteristic curve-area under the curve and area under the precision-recall curve in the test set for H&N small structures. For<i>D</i><sub>error, max</sub>, including dose metrics increased performance for H&N small structures, H&N medium structures, and GYN structures.<i>Significance.</i>In many instances, utilizing dose with geometric comparisons can improve the ability of a verification model to flag potential errors from a primary auto-contouring model.
Authors
- Dong Joo Rhee (ORCID: https://orcid.org/0000-0003-0486-1556)
- Surendra Prajapati (ORCID: https://orcid.org/0000-0003-3531-8054)
- Raymond Mumme (ORCID: https://orcid.org/0000-0001-7383-6122)
- David Fuentes (ORCID: https://orcid.org/0000-0002-2572-6962)
- Thomas J. Whitaker (ORCID: https://orcid.org/0000-0001-8950-9097)
- Barbara Marquez (ORCID: https://orcid.org/0000-0002-0070-6930)
- Laurence E. Court (ORCID: https://orcid.org/0000-0002-3241-6145)
- Anuja Jhingran (ORCID: https://orcid.org/0000-0002-0697-1815)
- Raphael Douglas (ORCID: https://orcid.org/0009-0004-7435-2997)
- Julianne Pollard‐Larkin (ORCID: https://orcid.org/0000-0002-1196-656X)
- Christine B. Peterson (ORCID: https://orcid.org/0000-0003-3316-0468)
Institutions
- The University of Texas MD Anderson Cancer Center (US)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2025-06-18
- DOI
- https://doi.org/10.1088/1361-6560/ade5e6
- Citations
- 1
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 1.88
Funders
- Cancer Prevention and Research Institute of Texas