Experimental assessment of CO2 rebreathing in closed-circuit CPAP therapy with different non-invasive interfaces
Continuous Positive Airway Pressure (CPAP) is a non-invasive ventilation therapy that supports respiratory function by improving functional residual capacity and maintaining open airways through positive pressure. Closed-circuit CPAP configurations are emerging as a promising alternative to conventional open circuits, offering several advantages. However, their effectiveness can be compromised by CO<sub>2</sub> rebreathing. This study aimed to quantify inhaled CO<sub>2</sub> levels during closed-circuit CPAP therapy with different interfaces and explore the effects of interface volume, inlet and outlet port position and airflow rates on CO<sub>2</sub> accumulation. Four helmets, differing in port positioning, and One-port and Two-ports total-face Masks were tested under three flow conditions (0, 60, and 80 l/min) using an ad hoc test bench to measure CO<sub>2</sub> accumulation inside the interface. Results demonstrated that interface design strongly influenced CO<sub>2</sub> retention. Lateral Inlet/Lateral Outlet Helmet (current commercial helmet) showed the highest inhaled CO<sub>2</sub> levels (about 2 %), while the Up Inlet/Front Outlet Helmet achieved lower inhaled CO<sub>2</sub> (0.6 % at 80 l/min). Masks, characterized by smaller volumes, consistently exhibited lower CO<sub>2</sub> retention. Notably, the Two-ports Mask maintained inhaled CO<sub>2</sub> levels below 1 % (patient safety threshold) even without additional recirculation airflow. Increasing flow rates effectively reduced CO<sub>2</sub> rebreathing, with the most pronounced reduction occurring between 0 and 60 l/min. These findings highlight the critical role of interface design, particularly port positioning, in minimizing CO<sub>2</sub> rebreathing. The results enabled selection of safe interfaces for closed-circuit CPAP. Furthermore, these findings can be extended to conventional open-circuit CPAP therapy, enhancing patient safety in non-invasive ventilation.
Authors
- Mara Terzini (ORCID: https://orcid.org/0000-0002-5699-6009)
- Giovanni Putame (ORCID: https://orcid.org/0000-0002-4585-0979)
- Alberto Audenino (ORCID: https://orcid.org/0000-0002-4877-3630)
- Simone Borrelli (ORCID: https://orcid.org/0000-0002-2433-5038)
- Andrea Formaggio (ORCID: https://orcid.org/0009-0007-8434-4044)
- Carlo Olivieri (ORCID: https://orcid.org/0000-0002-7858-8882)
- Margherita De Luca
Institutions
- Politecnico di Torino (IT)
- Azienda Sanitaria Locale Roma 3 (IT)
Publication Details
- Journal
- Journal of Biomechanics
- Published
- 2025-06-18
- DOI
- https://doi.org/10.1016/j.jbiomech.2025.112826
- Primary Topic
- Respiratory Support and Mechanisms
- Type
- article
- Field-Weighted Citation Impact
- 0.00