Comparative analysis of the heat transfer for a linear Fresnel reflector in Jordan

This study analyzes the potential occurrence of two-phase flow within the absorber tube of a Linear Fresnel Reflector (LFR) system installed at a factory in Amman, Jordan. The analysis compares the existing heat transfer fluid, water, with Therminol VP-1, a synthetic thermal oil, to address and mitigate challenges associated with two-phase flow formation. Using FluidFlow V3.44 software, simulations were conducted to evaluate temperature rise, output pressure, vapor quality, and the likelihood of two-phase flow under three distinct operational cases provided by the system operators. The results demonstrated that the simulations closely align with the actual system behavior for water. When Therminol VP-1 was analyzed under the same inlet conditions, it exhibited superior thermal stability by eliminating two-phase flow formation, and achieved an improved temperature profile compared to water such as the output temperature increased from 131.48 °C using water to 138.66 °C using Therminol VP-1, enhancing the overall performance of the LFR system stability. These findings position Therminol VP-1 as a viable and competitive alternative for improving the thermal performance and operational reliability of LFR systems.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-06-18
DOI
https://doi.org/10.1016/j.csite.2025.106533
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of the heat transfer for a linear Fresnel reflector in Jordan

Rami J. Haddad, Bashar R. Qawasmeh
4 links
Case Studies in Thermal Engineering
Solar Thermal and Photovoltaic Systems
article

Comparative analysis of the heat transfer for a linear Fresnel reflector in Jordan

Rami J. Haddad, Bashar R. Qawasmeh
article en

Abstract

This study analyzes the potential occurrence of two-phase flow within the absorber tube of a Linear Fresnel Reflector (LFR) system installed at a factory in Amman, Jordan. The analysis compares the existing heat transfer fluid, water, with Therminol VP-1, a synthetic thermal oil, to address and mitigate challenges associated with two-phase flow formation. Using FluidFlow V3.44 software, simulations were conducted to evaluate temperature rise, output pressure, vapor quality, and the likelihood of two-phase flow under three distinct operational cases provided by the system operators. The results demonstrated that the simulations closely align with the actual system behavior for water. When Therminol VP-1 was analyzed under the same inlet conditions, it exhibited superior thermal stability by eliminating two-phase flow formation, and achieved an improved temperature profile compared to water such as the output temperature increased from 131.48 °C using water to 138.66 °C using Therminol VP-1, enhancing the overall performance of the LFR system stability. These findings position Therminol VP-1 as a viable and competitive alternative for improving the thermal performance and operational reliability of LFR systems.

Case Studies in Thermal EngineeringVol. 73
University of Jordan (JO)
Affordable and clean energy
Openalex Percentile: Top 92%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparative analysis of the heat transfer for a linear Fresnel reflector in Jordan — Rami J. Haddad, Bashar R. Qawasmeh · Case Studies in Thermal Engineering (2025) | TGRS Research Map | TGRS