Management of shoulder prosthetic joint infections with humeral bone loss using a customizable articulating long stem spacer (The Frankenspacer)
Long-stem custom spacer placement using a prefabricated humeral head combined with a humeral nail (The Frankenspacer) for shoulder PJI and PHBL results in acceptable reinfection rates for patients undergoing a 2-stage revision. Glenohumeral dislocation and glenoid erosion are common. Dislocation increases with severity of PHBL. This technique is a reasonable treatment option for managing this complex patient population.
Authors
- Christopher D. Joyce (ORCID: https://orcid.org/0000-0003-2329-5334)
- Peter N. Chalmers (ORCID: https://orcid.org/0000-0002-1275-0285)
- Cameron Guy (ORCID: https://orcid.org/0000-0001-8493-449X)
- Robert Z. Tashjian (ORCID: https://orcid.org/0000-0003-4112-0423)
- Nikko D. Beady (ORCID: https://orcid.org/0009-0004-7096-3272)
Institutions
- University of Utah (US)
Publication Details
- Journal
- JSES Reviews Reports and Techniques
- Published
- 2025-06-18
- DOI
- https://doi.org/10.1016/j.xrrt.2025.06.002
- Primary Topic
- Orthopedic Infections and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- University of Utah
- Stryker