New Start-up Strategy for Dual-Active Bridge (DAB) Converter with Reduced Start-up Time

This study proposes a new start-up strategy to reduce start-up time. The conventional strategy uses a zero-voltage sequence to reduce inrush current and employs two modulations to reduce start-up time. This strategy has low conduction losses, but it suffers from large switching losses with MOSFETs and a long start-up time, which affect reliability. The proposed strategy can reduce start-up time by employing equivalent ZVS current modulation extended-phase shift (EZM-EPS) instead of triple-phase shift modulation (TPS). The proposed strategy can achieve a fast start-up, and the feasibility of its use is verified using a 600 W prototype under 100 V input and 100 V output conditions.

Authors

Publication Details

Journal
The Transactions of the Korean Institute of Power Electronics
Published
2025-06-19
DOI
https://doi.org/10.6113/tkpe.2025.30.3.208
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Start-up Strategy for Dual-Active Bridge (DAB) Converter with Reduced Start-up Time

Jae-Kuk Kim, Si-Won Kim, Ji‐Yeon Kim
The Transactions of the Korean Institute of Power Electronics
Advanced DC-DC Converters
article

New Start-up Strategy for Dual-Active Bridge (DAB) Converter with Reduced Start-up Time

Jae-Kuk Kim, Si-Won Kim, Ji‐Yeon Kim
article en

Abstract

This study proposes a new start-up strategy to reduce start-up time. The conventional strategy uses a zero-voltage sequence to reduce inrush current and employs two modulations to reduce start-up time. This strategy has low conduction losses, but it suffers from large switching losses with MOSFETs and a long start-up time, which affect reliability. The proposed strategy can reduce start-up time by employing equivalent ZVS current modulation extended-phase shift (EZM-EPS) instead of triple-phase shift modulation (TPS). The proposed strategy can achieve a fast start-up, and the feasibility of its use is verified using a 600 W prototype under 100 V input and 100 V output conditions.

The Transactions of the Korean Institute of Power ElectronicsVol. 30(3)
Affordable and clean energy
Openalex Percentile: Top 88%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

New Start-up Strategy for Dual-Active Bridge (DAB) Converter with Reduced Start-up Time — Jae-Kuk Kim, Si-Won Kim, et al. · The Transactions of the Korean Institute of Power Electronics (2025) | TGRS Research Map | TGRS