Accurate MRF‐Based 3D Multi‐Channel B<sub>1</sub><sup>+</sup> Mapping in the Human Body at 7 T

This work proposes a 3D multi-transmit channel B<sub>1</sub> <sup>+</sup> mapping approach based on magnetic resonance fingerprinting (MRF) for the human abdomen at 7 T. A stack-of-stars acquisition is employed to achieve motion-robust 3D encoding, along with a hybrid method where transmit (Tx) channel-wise B<sub>1</sub> <sup>+</sup> information is obtained through low flip angle GRE images. B<sub>1</sub> <sup>+</sup> mapping at ultra-high field (UHF) in the human abdomen is particularly challenging due to the large dynamic range of B<sub>1</sub> <sup>+</sup>, the extensive field of view (FOV), and the effects of respiratory motion. Few methods have been proposed to address these challenges, with a significant limitation being the relatively low RF power available at UHF, especially for pTx systems with a 8 × 1 kW power configuration. This limitation makes it difficult to achieve FAs greater than 30° in central body regions, which are required for accurate results with classical methods. In contrast, Tx channel-combined MRF-based B<sub>1</sub> <sup>+</sup> mapping has been validated as accurate for FAs greater than 6°, offering improved accuracy at low FAs. Here, two Tx channel-combined MRF-based B<sub>1</sub> <sup>+</sup> maps (B1-MRF) are acquired using two tailored complementary phase shims to obtain absolute B<sub>1</sub> <sup>+</sup> information across the entire FOV. The 3D hybrid approach was validated against a 2D reference using phantoms and in vivo free-breathing scans in three subjects with varying BMIs, where only one Tx channel was active at a time. The comparison showed strong agreement, with the 3D hybrid acquisition demonstrating improved performance in regions affected by flow, low FAs, or low signal-to-noise ratio compared to the 2D implementation. The higher accuracy and level of detail provided by the proposed method, in contrast to existing methods, are particularly relevant for several applications, including the validation of faster approaches, validation of electromagnetic simulations (which are safety-critical), and the creation of B<sub>1</sub> <sup>+</sup> map libraries for applications such as AI-based B<sub>1</sub> <sup>+</sup> mapping or universal pulse calculations.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2025-06-18
DOI
https://doi.org/10.1002/nbm.70080
Citations
3
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
4.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate MRF‐Based 3D Multi‐Channel B1+ Mapping in the Human Body at 7 T

Sebastian Schmitter, Felix Krueger, Max Lutz, Tobias Schaeffter et al.
3 citations
NMR in Biomedicine
Advanced MRI Techniques and Applications
4.08
article

Accurate MRF‐Based 3D Multi‐Channel B1+ Mapping in the Human Body at 7 T

Sebastian Schmitter, Felix Krueger, Max Lutz, Tobias Schaeffter, Sebastian Flassbeck, Christoph Stefan Aigner
article en
3 citations

Abstract

This work proposes a 3D multi-transmit channel B<sub>1</sub> <sup>+</sup> mapping approach based on magnetic resonance fingerprinting (MRF) for the human abdomen at 7 T. A stack-of-stars acquisition is employed to achieve motion-robust 3D encoding, along with a hybrid method where transmit (Tx) channel-wise B<sub>1</sub> <sup>+</sup> information is obtained through low flip angle GRE images. B<sub>1</sub> <sup>+</sup> mapping at ultra-high field (UHF) in the human abdomen is particularly challenging due to the large dynamic range of B<sub>1</sub> <sup>+</sup>, the extensive field of view (FOV), and the effects of respiratory motion. Few methods have been proposed to address these challenges, with a significant limitation being the relatively low RF power available at UHF, especially for pTx systems with a 8 × 1 kW power configuration. This limitation makes it difficult to achieve FAs greater than 30° in central body regions, which are required for accurate results with classical methods. In contrast, Tx channel-combined MRF-based B<sub>1</sub> <sup>+</sup> mapping has been validated as accurate for FAs greater than 6°, offering improved accuracy at low FAs. Here, two Tx channel-combined MRF-based B<sub>1</sub> <sup>+</sup> maps (B1-MRF) are acquired using two tailored complementary phase shims to obtain absolute B<sub>1</sub> <sup>+</sup> information across the entire FOV. The 3D hybrid approach was validated against a 2D reference using phantoms and in vivo free-breathing scans in three subjects with varying BMIs, where only one Tx channel was active at a time. The comparison showed strong agreement, with the 3D hybrid acquisition demonstrating improved performance in regions affected by flow, low FAs, or low signal-to-noise ratio compared to the 2D implementation. The higher accuracy and level of detail provided by the proposed method, in contrast to existing methods, are particularly relevant for several applications, including the validation of faster approaches, validation of electromagnetic simulations (which are safety-critical), and the creation of B<sub>1</sub> <sup>+</sup> map libraries for applications such as AI-based B<sub>1</sub> <sup>+</sup> mapping or universal pulse calculations.

NMR in BiomedicineVol. 38(8)
Physikalisch-Technische Bundesanstalt (DE), University of Minnesota (US), German Cancer Research Center (DE), Heidelberg University (DE), Einstein Center Digital Future (DE), Resonance Research (United States) (US), Technische Universität Berlin (DE), New York University (US)
Openalex Percentile: Top 6%
Advanced MRI Techniques and Applications
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.