Comparative Evaluation of Fracture Resistance in Implant-Supported Provisional Crowns Fabricated by Computer-Aided Design and Manufacturing, Three-Dimensional Printing, and Conventional Self-Curing

Aim and objectives This study aimed to assess the influence of three fabrication techniques, computer-aided design (CAD) and computer-aided manufacturing (CAM) milling, three-dimensional (3D) printing, and conventional self-curing, on the fracture resistance of implant-supported polymethyl methacrylate (PMMA) resin-based provisional crowns. Methods An in vitro comparative study was conducted using 45 implant analogs with straight titanium abutments, equally distributed into three groups. Each analog was embedded vertically in custom acrylic resin blocks (20 × 20 × 20 mm). Abutments were torqued to 25 Ncm, and screw access channels were sealed with Teflon pellets and composite resin. Provisional crowns were fabricated using CAD-CAM milling, 3D printing, and conventional self-curing methods. All crowns were cemented and subjected to axial loading in a universal testing machine until fracture. Fracture resistance values were recorded and statistically analyzed. Results Crowns made with 3D printing showed the greatest average resistance to fracture, followed by CAD-CAM milling, and the crowns fabricated using the conventional self-curing method had the lowest fracture resistance. Statistical tests confirmed that these differences between the three groups were significant (p <0.05). The stronger performance of the 3D-printed crowns points to better overall durability, suggesting they could be especially useful for implant-supported provisional restorations in clinical practice. Conclusion Taking into account the limitations of this laboratory study, 3D-printed PMMA crowns showed the highest fracture resistance compared to the other fabrication methods tested. Crowns made by CAD-CAM milling also had strength levels that are acceptable for clinical use, making them a good alternative option. On the other hand, crowns produced with conventional self-curing methods were the least resistant to fracture, which means they might only be suitable for situations where the load is minimal. Ultimately, the choice of fabrication technique should be based on specific clinical requirements, material properties, and cost considerations.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-06-18
DOI
https://doi.org/10.7759/cureus.86311
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Evaluation of Fracture Resistance in Implant-Supported Provisional Crowns Fabricated by Computer-Aided Design and Manufacturing, Three-Dimensional Printing, and Conventional Self-Curing

Amit Kumar Rana, Anshuman Chaturvedi, Abhishek Singh, Abhinav Shekhar et al.
Cureus
Dental materials and restorations
article

Comparative Evaluation of Fracture Resistance in Implant-Supported Provisional Crowns Fabricated by Computer-Aided Design and Manufacturing, Three-Dimensional Printing, and Conventional Self-Curing

Amit Kumar Rana, Anshuman Chaturvedi, Abhishek Singh, Abhinav Shekhar, Shitij Srivastava, Love Kumar Bhatia
article en

Abstract

Aim and objectives This study aimed to assess the influence of three fabrication techniques, computer-aided design (CAD) and computer-aided manufacturing (CAM) milling, three-dimensional (3D) printing, and conventional self-curing, on the fracture resistance of implant-supported polymethyl methacrylate (PMMA) resin-based provisional crowns. Methods An in vitro comparative study was conducted using 45 implant analogs with straight titanium abutments, equally distributed into three groups. Each analog was embedded vertically in custom acrylic resin blocks (20 × 20 × 20 mm). Abutments were torqued to 25 Ncm, and screw access channels were sealed with Teflon pellets and composite resin. Provisional crowns were fabricated using CAD-CAM milling, 3D printing, and conventional self-curing methods. All crowns were cemented and subjected to axial loading in a universal testing machine until fracture. Fracture resistance values were recorded and statistically analyzed. Results Crowns made with 3D printing showed the greatest average resistance to fracture, followed by CAD-CAM milling, and the crowns fabricated using the conventional self-curing method had the lowest fracture resistance. Statistical tests confirmed that these differences between the three groups were significant (p <0.05). The stronger performance of the 3D-printed crowns points to better overall durability, suggesting they could be especially useful for implant-supported provisional restorations in clinical practice. Conclusion Taking into account the limitations of this laboratory study, 3D-printed PMMA crowns showed the highest fracture resistance compared to the other fabrication methods tested. Crowns made by CAD-CAM milling also had strength levels that are acceptable for clinical use, making them a good alternative option. On the other hand, crowns produced with conventional self-curing methods were the least resistant to fracture, which means they might only be suitable for situations where the load is minimal. Ultimately, the choice of fabrication technique should be based on specific clinical requirements, material properties, and cost considerations.

CureusVol. 17(6)
Sardar Patel Post Graduate Institute of Dental and Medical Sciences (IN)
Openalex Percentile: Top 85%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.