Optimal Configuration of Distribution Network Feeder Terminals Considering Distributed Power Sources

This paper proposes an optimal configuration strategy for Feeder Terminal Units (FTUs) in distribution networks, considering the impact of Distributed Generation (DG). Firstly, the impact of different FTU configurations on load interruption duration is analyzed, and areas are divided based on the proposed installation locations of FTUs, with load interruption loss models established for different areas. Secondly, a full probability model is introduced to calculate the probability of DG islanding under fault conditions, and its importance weight is determined according to DG capacity, thereby constructing a photovoltaic islanding loss model. Then, an optimal configuration model is established, with power supply reliability as a constraint, and minimizing the weighted sum of FTU installation costs, load interruption losses, and DG islanding losses as the objective. Finally, the accuracy of the proposed optimization model is verified through the IEEE 33-bus distribution network model.

Authors

Institutions

Publication Details

Published
2025-04-18
DOI
https://doi.org/10.1109/eeice65049.2025.11034036
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Configuration of Distribution Network Feeder Terminals Considering Distributed Power Sources

Haoqing Wang, Guanglin Sha, Ning Liu, Caihong Zhao et al.
Optimal Power Flow Distribution
article

Optimal Configuration of Distribution Network Feeder Terminals Considering Distributed Power Sources

Haoqing Wang, Guanglin Sha, Ning Liu, Caihong Zhao, Qiangsheng Bu
article en

Abstract

This paper proposes an optimal configuration strategy for Feeder Terminal Units (FTUs) in distribution networks, considering the impact of Distributed Generation (DG). Firstly, the impact of different FTU configurations on load interruption duration is analyzed, and areas are divided based on the proposed installation locations of FTUs, with load interruption loss models established for different areas. Secondly, a full probability model is introduced to calculate the probability of DG islanding under fault conditions, and its importance weight is determined according to DG capacity, thereby constructing a photovoltaic islanding loss model. Then, an optimal configuration model is established, with power supply reliability as a constraint, and minimizing the weighted sum of FTU installation costs, load interruption losses, and DG islanding losses as the objective. Finally, the accuracy of the proposed optimization model is verified through the IEEE 33-bus distribution network model.

North China Electric Power University (CN), Shanghai Electric (China) (CN), China Electric Power Research Institute
State Grid Corporation of China
Affordable and clean energy
Openalex Percentile: Top 88%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.