EVALUATION OF GRADUAL MASS LOSS OF DIFFERENT NICKEL-TITANIUM INSTRUMENTS AFTER REPEATED USES IN SIMULATED CANALS

The aim of this study was to evaluate the gradual mass loss of different nickel-titanium (NiTi) instruments after repeated uses in simulated canals. Four different instrument systems were used: Group 1. Protaper Ultimate®; Group 2. Trunatomy®; Group 3. Wave One Gold® and Group 4. Reciproc Blue®. Each instrument from each group was initially weighed on a high-precision digital analytical scale to obtain the initial weight (IW). Each group performed the instrumentation of five simulated canals using the X-Smart Plus® electric motor, following each manufacturer's sequence. After this step, a new weighing was performed to obtain the final weight (FW). The gradual mass loss of each instrument was calculated by the difference between the IW and FW of each instrument. After obtaining the results, statistical analysis was performed. After verifying the sample normality, an analysis of variance (P <0.05) was performed. The Tukey test was then used for multiple comparisons between the groups.

Authors

Publication Details

Journal
CIPEEX
Published
2024-12-30
DOI
https://doi.org/10.37951/2596-1578.cipeex.2024.12283
Primary Topic
Endodontics and Root Canal Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF GRADUAL MASS LOSS OF DIFFERENT NICKEL-TITANIUM INSTRUMENTS AFTER REPEATED USES IN SIMULATED CANALS

Harley Francisco de Oliveira, Helder Fernandes de Oliveira, Orlando Aguirre Guedes, Ana Maria Maia Rodrigues et al.
1 links
CIPEEX
Endodontics and Root Canal Treatments
article

EVALUATION OF GRADUAL MASS LOSS OF DIFFERENT NICKEL-TITANIUM INSTRUMENTS AFTER REPEATED USES IN SIMULATED CANALS

Harley Francisco de Oliveira, Helder Fernandes de Oliveira, Orlando Aguirre Guedes, Ana Maria Maia Rodrigues, Mônica Misaé Endo, Naira Geovana Camilo, Lara Moisés Silva
article en

Abstract

The aim of this study was to evaluate the gradual mass loss of different nickel-titanium (NiTi) instruments after repeated uses in simulated canals. Four different instrument systems were used: Group 1. Protaper Ultimate®; Group 2. Trunatomy®; Group 3. Wave One Gold® and Group 4. Reciproc Blue®. Each instrument from each group was initially weighed on a high-precision digital analytical scale to obtain the initial weight (IW). Each group performed the instrumentation of five simulated canals using the X-Smart Plus® electric motor, following each manufacturer's sequence. After this step, a new weighing was performed to obtain the final weight (FW). The gradual mass loss of each instrument was calculated by the difference between the IW and FW of each instrument. After obtaining the results, statistical analysis was performed. After verifying the sample normality, an analysis of variance (P <0.05) was performed. The Tukey test was then used for multiple comparisons between the groups.

CIPEEXVol. 5(2)
Openalex Percentile: Top 58%
Endodontics and Root Canal Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.