Circuit design for broadband decoupling in multi-coil multi-nuclear applications

The wealth of information available from multinuclear magnetic resonance imaging and spectroscopy is largely untapped in the clinical setting. This is due to a multitude of challenges in the pipeline ranging from acquisition strategies, hardware design, processing, and interpretation/analysis. As a small part of addressing these challenges, this work presents a straightforward approach for broadband decoupling between coils. This circuit was created with the implementation of a series PIN diode and was evaluated on the bench and experimentally for <sup>1</sup>H, <sup>31</sup>P and <sup>23</sup>Na at 3 T. Individual coils were single-tuned with this decoupling network and stacked to enable a switched triple-tuned coil. These coils were evaluated in various purposefully coupled configurations and compared to a narrowband trap active detuning network to demonstrate potential modularity of this design. Narrowband trapped coils showed drops in SNR when combined with other coils, presumably due to coupling between receiver elements tuned to different frequencies. This broadband decoupling behavior was shown to be independent of positioning through coils oriented to be nearly perfectly geometrically coupled and the addition of a three-element array of the same size. This configuration was validated on a post-mortem pig to verify the losses of the network did not prohibit its use for preclinical imaging and spectroscopy applications. Although losses were incurred as a result of the broadband decoupling network, it enabled a modular design that can be adapted to a given study without significant compromise of the signal integrity and could eliminate the need for certain custom coils for multi-nuclear studies.

Authors

Institutions

Publication Details

Journal
Journal of Magnetic Resonance
Published
2025-06-18
DOI
https://doi.org/10.1016/j.jmr.2025.107924
Primary Topic
Advanced NMR Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Circuit design for broadband decoupling in multi-coil multi-nuclear applications

Edith Touchet-Valle, Mary P. McDougall, Joseph Busher, Jacob Degitz
Journal of Magnetic Resonance
Advanced NMR Techniques and Applications
article

Circuit design for broadband decoupling in multi-coil multi-nuclear applications

Edith Touchet-Valle, Mary P. McDougall, Joseph Busher, Jacob Degitz
article en

Abstract

The wealth of information available from multinuclear magnetic resonance imaging and spectroscopy is largely untapped in the clinical setting. This is due to a multitude of challenges in the pipeline ranging from acquisition strategies, hardware design, processing, and interpretation/analysis. As a small part of addressing these challenges, this work presents a straightforward approach for broadband decoupling between coils. This circuit was created with the implementation of a series PIN diode and was evaluated on the bench and experimentally for <sup>1</sup>H, <sup>31</sup>P and <sup>23</sup>Na at 3 T. Individual coils were single-tuned with this decoupling network and stacked to enable a switched triple-tuned coil. These coils were evaluated in various purposefully coupled configurations and compared to a narrowband trap active detuning network to demonstrate potential modularity of this design. Narrowband trapped coils showed drops in SNR when combined with other coils, presumably due to coupling between receiver elements tuned to different frequencies. This broadband decoupling behavior was shown to be independent of positioning through coils oriented to be nearly perfectly geometrically coupled and the addition of a three-element array of the same size. This configuration was validated on a post-mortem pig to verify the losses of the network did not prohibit its use for preclinical imaging and spectroscopy applications. Although losses were incurred as a result of the broadband decoupling network, it enabled a modular design that can be adapted to a given study without significant compromise of the signal integrity and could eliminate the need for certain custom coils for multi-nuclear studies.

Journal of Magnetic ResonanceVol. 378
Texas A&M University (US)
National Institutes of Health
Affordable and clean energy
Openalex Percentile: Top 87%
Advanced NMR Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Circuit design for broadband decoupling in multi-coil multi-nuclear applications — Edith Touchet-Valle, Mary P. McDougall, et al. · Journal of Magnetic Resonance (2025) | TGRS Research Map | TGRS