FRP-RC columns reinforced with novel FRP strip spiral: Axial compression tests and theoretical model

• A new type of GFRP strip spiral (N-GFRP) formed by vacuum negative pressure process is 4 proposed. • Axial compression tests of 12 FRP-RC columns reinforced with N-GFRP are conducted. • The confinement efficiency of N-GFRP spirals is higher than the traditional rod-shaped stirrups. • A strength design equation for FRP-RC columns reinforced with N-GFRP spiral is proposed 8 and verified. Traditional rod-shaped fiber reinforced polymer (FRP) stirrups face challenges such as fiber kinking, strength reduction at bends, and slip failure at lap joints, compromising concrete confinement and ductility. To address these issues, this study proposes a novel glass FRP (GFRP) strip spiral (N-GFRP) fabricated via vacuum-assisted winding. Axial compression tests on 12 circular concrete columns (200 × 600 mm) reinforced with N-GFRP spirals or traditional rod-shaped GFRP stirrups were conducted. Results demonstrate that N-GFRP spirals eliminate lap-slip failure, enhancing confinement efficiency. Columns with N-GFRP spirals exhibited 12.8 % and 20.9 % higher peak axial load capacity compared to those with traditional stirrups for GFRP and steel longitudinal bars, respectively, alongside ductility improvements of 16.3 % and 4.3 %. Finally, the predictions from existing constitutive models of FRP confined concrete are compared with the experimental results, and the effective coefficient of the most accurate model is refined for concrete confined with N-GFRP spiral. Furthermore, a strength design equation for FRP-RC columns reinforced with N-GFRP spiral is proposed and verified. This work highlights the superior performance of N-GFRP spirals, providing a viable solution for durable and high-capacity FRP-reinforced concrete structures.

Authors

Institutions

Publication Details

Journal
Composite Structures
Published
2025-06-18
DOI
https://doi.org/10.1016/j.compstruct.2025.119411
Citations
2
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FRP-RC columns reinforced with novel FRP strip spiral: Axial compression tests and theoretical model

Kaiquan Liu, Yan Zhuge, Lik‐ho Tam, Ruixin Jia et al.
2 citations
Composite Structures
Structural Behavior of Reinforced Concrete
2.01
article

FRP-RC columns reinforced with novel FRP strip spiral: Axial compression tests and theoretical model

Kaiquan Liu, Yan Zhuge, Lik‐ho Tam, Ruixin Jia, Jun‐Jie Zeng, Yue Liu
article en
2 citations

Abstract

• A new type of GFRP strip spiral (N-GFRP) formed by vacuum negative pressure process is 4 proposed. • Axial compression tests of 12 FRP-RC columns reinforced with N-GFRP are conducted. • The confinement efficiency of N-GFRP spirals is higher than the traditional rod-shaped stirrups. • A strength design equation for FRP-RC columns reinforced with N-GFRP spiral is proposed 8 and verified. Traditional rod-shaped fiber reinforced polymer (FRP) stirrups face challenges such as fiber kinking, strength reduction at bends, and slip failure at lap joints, compromising concrete confinement and ductility. To address these issues, this study proposes a novel glass FRP (GFRP) strip spiral (N-GFRP) fabricated via vacuum-assisted winding. Axial compression tests on 12 circular concrete columns (200 × 600 mm) reinforced with N-GFRP spirals or traditional rod-shaped GFRP stirrups were conducted. Results demonstrate that N-GFRP spirals eliminate lap-slip failure, enhancing confinement efficiency. Columns with N-GFRP spirals exhibited 12.8 % and 20.9 % higher peak axial load capacity compared to those with traditional stirrups for GFRP and steel longitudinal bars, respectively, alongside ductility improvements of 16.3 % and 4.3 %. Finally, the predictions from existing constitutive models of FRP confined concrete are compared with the experimental results, and the effective coefficient of the most accurate model is refined for concrete confined with N-GFRP spiral. Furthermore, a strength design equation for FRP-RC columns reinforced with N-GFRP spiral is proposed and verified. This work highlights the superior performance of N-GFRP spirals, providing a viable solution for durable and high-capacity FRP-reinforced concrete structures.

Composite StructuresVol. 370
University of South Australia (AU), Beijing University of Technology (CN), Weichai Power (China) (CN), Beihang University (CN), University of Science and Technology Beijing (CN)
National Natural Science Foundation of China, Natural Science Foundation of Guangdong Province, Australian Research Council
Sustainable cities and communities
Openalex Percentile: Top 14%
Structural Behavior of Reinforced Concrete
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.