Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms

Lateral flow assays (LFAs) are widely favored for on-site analysis due to their simplicity and cost-effectiveness. However, their limited quantitative capabilities constrain them to qualitative testing. In contrast, etalon sensors offer high sensitivity and enable quantitative detection. They operate by producing interference-based optical signals through multiple reflections of light within a cavity formed by two parallel reflective surfaces. This requires a stable optical path length, traditionally limiting their use to smooth substrates. This study presents an integrated separation-sensing microfluidic platform (EtLFA). By fabricating etalons on commercial membranes and evaluating sensor's sensitivity and surface roughness, we determined that membrane surface roughness must meet two criteria - Sa < 0.5 μm and Smr > 90% - to support functional etalons. Capillary and permeability remain intact after etalon integration, ensuring membrane's purification performance. We further functionalized the etalon to respond specifically to glucose, to demonstrate the quantitative detection of glucose levels in a mimic blood sample. A glucose-responsive etalon@nylon served as the sensor module, while regenerated cellulose membrane enabled separation. This dual-module configuration filtered PDMS particles mimicking red blood cells and produced a 25 nm shift for 100 mg/dL glucose, enabling linear quantification via portable spectrometry. By incorporating etalon sensor onto rough membrane substrates, our platform transforms conventional LFAs into a quantitative analytical tool, offering novel avenues for enhancing analytical capabilities and broadening the applications of lateral flow assays.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-06-18
DOI
https://doi.org/10.1016/j.bios.2025.117656
Citations
2
Primary Topic
Electrowetting and Microfluidic Technologies
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms

Arjo J. Loeve, Michael J. Serpe, Hanieh Bazyar, Meng-Meng Zhang
2 citations
Biosensors and Bioelectronics
Electrowetting and Microfluidic Technologies
1.46
article

Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms

Arjo J. Loeve, Michael J. Serpe, Hanieh Bazyar, Meng-Meng Zhang
article en
2 citations

Abstract

Lateral flow assays (LFAs) are widely favored for on-site analysis due to their simplicity and cost-effectiveness. However, their limited quantitative capabilities constrain them to qualitative testing. In contrast, etalon sensors offer high sensitivity and enable quantitative detection. They operate by producing interference-based optical signals through multiple reflections of light within a cavity formed by two parallel reflective surfaces. This requires a stable optical path length, traditionally limiting their use to smooth substrates. This study presents an integrated separation-sensing microfluidic platform (EtLFA). By fabricating etalons on commercial membranes and evaluating sensor's sensitivity and surface roughness, we determined that membrane surface roughness must meet two criteria - Sa < 0.5 μm and Smr > 90% - to support functional etalons. Capillary and permeability remain intact after etalon integration, ensuring membrane's purification performance. We further functionalized the etalon to respond specifically to glucose, to demonstrate the quantitative detection of glucose levels in a mimic blood sample. A glucose-responsive etalon@nylon served as the sensor module, while regenerated cellulose membrane enabled separation. This dual-module configuration filtered PDMS particles mimicking red blood cells and produced a 25 nm shift for 100 mg/dL glucose, enabling linear quantification via portable spectrometry. By incorporating etalon sensor onto rough membrane substrates, our platform transforms conventional LFAs into a quantitative analytical tool, offering novel avenues for enhancing analytical capabilities and broadening the applications of lateral flow assays.

Biosensors and BioelectronicsVol. 287
University of Alberta (CA), Delft University of Technology (NL)
Technische Universiteit Delft
Openalex Percentile: Top 17%
Electrowetting and Microfluidic Technologies
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.