Assessment of reconstruction accuracy for under-sampled 31P-MRS data using compressed sensing and a low rank Hankel matrix completion approach

Phosphorus magnetic resonance spectroscopy and spectroscopic imaging (<sup>31</sup>P-MRS/MRSI) are techniques to evaluate energy metabolism <i>in vivo</i>, they are capable of measuring metabolites such as phosphocreatine and inorganic phosphate in muscle and brain tissue. Despite their capability, these techniques are not very often used in clinical settings due to the long acquisition times required. In recent years, compressed sensing has been widely used as an acceleration method for MRI signal acquisition and translated to MRS. In order to use it, one of the main criteria states that the aliasing resulting from the undersampling scheme must be incoherent, which is achieved using a pseudo-random sampling strategy. However, when a set of pseudo-random sampling patterns are applied for the same acceleration factor, there is significant variability in the quality of the reconstructed signal. We present an evaluation of the influence of the undersampling pattern in the quality of the signal reconstruction through a series of experiments in <sup>31</sup>P-MRS data using the low rank Hankel matrix completion as the reconstruction method. Our results demonstrate that the reconstruction accuracy is heavily influenced by the selection of specific samples rather than the undersampling factor. Furthermore, the noise level in the signal has a more pronounced impact on reconstruction quality. Additionally, reconstruction accuracy is significantly correlated with the density of samples collected at early sampling times, making it possible to set large time values to zero without producing any statistical difference in the error distribution means for some cases.

Authors

Institutions

Publication Details

Journal
Frontiers in Endocrinology
Published
2025-06-17
DOI
https://doi.org/10.3389/fendo.2025.1581328
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of reconstruction accuracy for under-sampled 31P-MRS data using compressed sensing and a low rank Hankel matrix completion approach

Alejandro Santos‐Díaz, J. A. García, Michael D. Noseworthy
Frontiers in Endocrinology
Advanced MRI Techniques and Applications
article

Assessment of reconstruction accuracy for under-sampled 31P-MRS data using compressed sensing and a low rank Hankel matrix completion approach

Alejandro Santos‐Díaz, J. A. García, Michael D. Noseworthy
article en

Abstract

Phosphorus magnetic resonance spectroscopy and spectroscopic imaging (<sup>31</sup>P-MRS/MRSI) are techniques to evaluate energy metabolism <i>in vivo</i>, they are capable of measuring metabolites such as phosphocreatine and inorganic phosphate in muscle and brain tissue. Despite their capability, these techniques are not very often used in clinical settings due to the long acquisition times required. In recent years, compressed sensing has been widely used as an acceleration method for MRI signal acquisition and translated to MRS. In order to use it, one of the main criteria states that the aliasing resulting from the undersampling scheme must be incoherent, which is achieved using a pseudo-random sampling strategy. However, when a set of pseudo-random sampling patterns are applied for the same acceleration factor, there is significant variability in the quality of the reconstructed signal. We present an evaluation of the influence of the undersampling pattern in the quality of the signal reconstruction through a series of experiments in <sup>31</sup>P-MRS data using the low rank Hankel matrix completion as the reconstruction method. Our results demonstrate that the reconstruction accuracy is heavily influenced by the selection of specific samples rather than the undersampling factor. Furthermore, the noise level in the signal has a more pronounced impact on reconstruction quality. Additionally, reconstruction accuracy is significantly correlated with the density of samples collected at early sampling times, making it possible to set large time values to zero without producing any statistical difference in the error distribution means for some cases.

Frontiers in EndocrinologyVol. 16
McMaster University (CA), Tecnológico de Monterrey (MX)
Openalex Percentile: Top 79%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of reconstruction accuracy for under-sampled 31P-MRS data using compressed sensing and a low rank Hankel matrix completion approach — Alejandro Santos‐Díaz, J. A. García, et al. · Frontiers in Endocrinology (2025) | TGRS Research Map | TGRS