Effect of combined lateral and supine positioning on oxygen saturation in ICU patients during the mechanical ventilator weaning process: A randomized controlled trial

Background: Prolonged mechanical ventilation in ICU patients increases mortality risk and length of stay.Ineffective weaning can exacerbate the patient's condition and further elevate mortality risk due to hypoxemiainduced cellular damage, contributing to ICU overcrowding.Purpose: This study investigates the effect of lateral positioning on oxygen saturation in ICU patients undergoing mechanical ventilator weaning.Methods: A randomized controlled trial (RCT) with block randomization was conducted, enrolling 60 participants assigned to either the intervention group (n = 30) or the control group (n = 30).The intervention group received 5% FiO 2 and was repositioned every two hours (right lateral, supine, left lateral), whereas the control group remained supine with 5% FiO 2 .Oxygen saturation (SaO 2 ) was measured using pulse oximetry before and after the intervention.As the data were not normally distributed, the Mann-Whitney U test was used to compare SaO 2 changes between groups, with statistical significance set at p < 0.05.Results: Baseline characteristics, including age, gender, and ventilator duration, were comparable between groups (p > 0.05).The median increase in SaO 2 was 6% (IQR: 1-8%) in the intervention group and 1% (IQR: 0-3%) in the control group, with a significant between-group difference of 5% (p < 0.001).A large effect size ( = 0.68) indicated a substantial impact of lateral positioning on SaO 2 .Conclusions: Lateral positioning significantly improves oxygen saturation in ICU patients undergoing ventilator weaning, potentially reducing complications associated with prolonged mechanical ventilation.

Authors

Institutions

Publication Details

Journal
Jurnal Keperawatan Padjadjaran
Published
2025-04-25
DOI
https://doi.org/10.24198/jkp.v13i1.2431
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of combined lateral and supine positioning on oxygen saturation in ICU patients during the mechanical ventilator weaning process: A randomized controlled trial

Sidik Awaludin, Ikit Netra Wirakhmi, Iwan Purnawan, Galih Noor Alivian et al.
Jurnal Keperawatan Padjadjaran
Respiratory Support and Mechanisms
article

Effect of combined lateral and supine positioning on oxygen saturation in ICU patients during the mechanical ventilator weaning process: A randomized controlled trial

Sidik Awaludin, Ikit Netra Wirakhmi, Iwan Purnawan, Galih Noor Alivian, Arif Imam Hidayat, Putut Anggara Susetya, Sawinee Chanshintop
article en

Abstract

Background: Prolonged mechanical ventilation in ICU patients increases mortality risk and length of stay.Ineffective weaning can exacerbate the patient's condition and further elevate mortality risk due to hypoxemiainduced cellular damage, contributing to ICU overcrowding.Purpose: This study investigates the effect of lateral positioning on oxygen saturation in ICU patients undergoing mechanical ventilator weaning.Methods: A randomized controlled trial (RCT) with block randomization was conducted, enrolling 60 participants assigned to either the intervention group (n = 30) or the control group (n = 30).The intervention group received 5% FiO 2 and was repositioned every two hours (right lateral, supine, left lateral), whereas the control group remained supine with 5% FiO 2 .Oxygen saturation (SaO 2 ) was measured using pulse oximetry before and after the intervention.As the data were not normally distributed, the Mann-Whitney U test was used to compare SaO 2 changes between groups, with statistical significance set at p < 0.05.Results: Baseline characteristics, including age, gender, and ventilator duration, were comparable between groups (p > 0.05).The median increase in SaO 2 was 6% (IQR: 1-8%) in the intervention group and 1% (IQR: 0-3%) in the control group, with a significant between-group difference of 5% (p < 0.001).A large effect size ( = 0.68) indicated a substantial impact of lateral positioning on SaO 2 .Conclusions: Lateral positioning significantly improves oxygen saturation in ICU patients undergoing ventilator weaning, potentially reducing complications associated with prolonged mechanical ventilation.

Jurnal Keperawatan PadjadjaranVol. 13(1)
Jenderal Soedirman University (ID), Harapan Bangsa Institute of Technology (ID), Princess of Naradhiwas University (TH), Hospital Perpetuo Socorro (ES)
Jenderal Soedirman University
Openalex Percentile: Top 77%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.