Evaluation of refrigerant oil separators for screw chiller

Effective refrigerant and oil separation is must for reliable and energy efficient chiller operation. Type A is a conventional oil separator design having a larger shell diameter and single refrigerant outlet connected to condenser using a discharge piping. Type B is novel oil separator design having a smaller shell diameter and two refrigerant outlets connected to the condenser. The CFD simulation of both designs is done for comparing oil separation efficiencies, velocity distribution, pressure drop and oil droplet trajectories. The simulated pressure drop matches closely (< 5%) with experimental results in both designs. Type A design has higher (10912 Pa) pressure drop than Type B design. Simulation shows both the designs have almost equivalent oil separation efficiency at and above 25 ?m oil droplet sizes. Below 25 ?m oil droplet sizes, the Type B design has better oil separation efficiency. Chiller with Type B design has better oil circulation rates in liquid refrigerant than the chiller with Type A design at maximum flow rate condition. Therefore, Type B oil separator is found to be superior in performance (lower pressure drop and lower oil circulation rates) at lesser cost. Chiller with Type B oil separator is having 0.5% more refrigeration capacity, 1.6% higher COP and 1.1% lower power consumption than chiller with Type A oil separator.

Authors

Institutions

Publication Details

Journal
Thermal Science
Published
2025-06-17
DOI
https://doi.org/10.2298/tsci250122100m
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of refrigerant oil separators for screw chiller

Virendra Bhojwani, Amey Majgaonkar, A. Karthikeyan
Thermal Science
Refrigeration and Air Conditioning Technologies
article

Evaluation of refrigerant oil separators for screw chiller

Virendra Bhojwani, Amey Majgaonkar, A. Karthikeyan
article en

Abstract

Effective refrigerant and oil separation is must for reliable and energy efficient chiller operation. Type A is a conventional oil separator design having a larger shell diameter and single refrigerant outlet connected to condenser using a discharge piping. Type B is novel oil separator design having a smaller shell diameter and two refrigerant outlets connected to the condenser. The CFD simulation of both designs is done for comparing oil separation efficiencies, velocity distribution, pressure drop and oil droplet trajectories. The simulated pressure drop matches closely (< 5%) with experimental results in both designs. Type A design has higher (10912 Pa) pressure drop than Type B design. Simulation shows both the designs have almost equivalent oil separation efficiency at and above 25 ?m oil droplet sizes. Below 25 ?m oil droplet sizes, the Type B design has better oil separation efficiency. Chiller with Type B design has better oil circulation rates in liquid refrigerant than the chiller with Type A design at maximum flow rate condition. Therefore, Type B oil separator is found to be superior in performance (lower pressure drop and lower oil circulation rates) at lesser cost. Chiller with Type B oil separator is having 0.5% more refrigeration capacity, 1.6% higher COP and 1.1% lower power consumption than chiller with Type A oil separator.

Thermal ScienceVol. 30(1 Part B)
MIT Art, Design and Technology University (IN), Sathyabama Institute of Science and Technology (IN)
Openalex Percentile: Top 86%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of refrigerant oil separators for screw chiller — Virendra Bhojwani, Amey Majgaonkar, et al. · Thermal Science (2025) | TGRS Research Map | TGRS