Measurement of Low-Concentration Hydrogen in Inert Gas Within a Small Closed Volume

A technique has been proposed and experimentally tested for measuring the hydrogen concentration in an inert atmosphere within a closed system. This method utilizes a metal-oxide-semiconductor field-effect capacity-type (MOSFEC) sensor under harsh conditions such as exposure to inert gases, pressure fluctuations, and varying temperatures. The measurement is performed during the thermal decomposition of metal hydrides in a liquid sodium environment. The developed measurement technique for determining hydrogen concentration released from metal hydride samples in a system with a closed gas path is cost-effective compared to standardized, resource-intensive open-volume flow measurement methods. The use of the developed MOSFEC sensor technique allows for rapid and efficient investigation of the in situ real-time dynamics of gas release from various metal hydride materials differing in their hydrogen content within a small closed volume. Additionally, this approach enables precise determination of the specific gas release temperatures.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-17
DOI
https://doi.org/10.3390/s25123771
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Low-Concentration Hydrogen in Inert Gas Within a Small Closed Volume

D. P. Shornikov, Maya Etrekova, Konstantin Oblov, Nikolay Samotaev et al.
Sensors
Gas Sensing Nanomaterials and Sensors
article

Measurement of Low-Concentration Hydrogen in Inert Gas Within a Small Closed Volume

D. P. Shornikov, Maya Etrekova, Konstantin Oblov, Nikolay Samotaev, Г. А. Иванов, А. В. Литвинов
article en

Abstract

A technique has been proposed and experimentally tested for measuring the hydrogen concentration in an inert atmosphere within a closed system. This method utilizes a metal-oxide-semiconductor field-effect capacity-type (MOSFEC) sensor under harsh conditions such as exposure to inert gases, pressure fluctuations, and varying temperatures. The measurement is performed during the thermal decomposition of metal hydrides in a liquid sodium environment. The developed measurement technique for determining hydrogen concentration released from metal hydride samples in a system with a closed gas path is cost-effective compared to standardized, resource-intensive open-volume flow measurement methods. The use of the developed MOSFEC sensor technique allows for rapid and efficient investigation of the in situ real-time dynamics of gas release from various metal hydride materials differing in their hydrogen content within a small closed volume. Additionally, this approach enables precise determination of the specific gas release temperatures.

SensorsVol. 25(12)
National Research Nuclear University MEPhI (RU)
Russian Science Foundation
Openalex Percentile: Top 88%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measurement of Low-Concentration Hydrogen in Inert Gas Within a Small Closed Volume — D. P. Shornikov, Maya Etrekova, et al. · Sensors (2025) | TGRS Research Map | TGRS