Patch-type wearable electrocardiography and impedance pneumography for sleep staging: A multi-modal deep learning approach

Sleep staging is critical for investigating sleep quality and detecting disorders. Polysomnography (PSG) remains the gold standard, but is costly and impractical for routine monitoring. This study evaluates the feasibility of a patch-type wearable device using single-lead electrocardiography (ECG) and impedance pneumography (IPG) for multi-stage sleep classification. Data from 92 patients were collected using a wearable ECG-IPG device. Preprocessing entailed bandpass filtering, segmentation into 5-min windows with 30-s overlaps, and feature extraction in time, frequency, and nonlinear domains. Three classification methods were tested and validated using 5-fold patient-independent cross-validation across 2-class (Wake, Sleep), 3-class (Wake, rapid eye movement (REM), and Non-REM), and 4-class (Wake, REM, N1, and N2) tasks. The combined approach achieved the highest accuracy in the 2-class task (accuracy: 83.6%, area under the receiver operating characteristic (AUROC): 86.0%). For 3- and 4-class tasks, feature-based methods outperformed the others, with the RCNN achieving the best F1-score (0.618 in 3-class and 0.552 in 4-class). Modality analysis revealed that IPG + R-R interval (RRI) + motion sensors provided the highest performance, with IPG and RRI identified as the most effective in sleep staging. Feature reduction using maximum relevance and minimum redundancy (mRMR) identified the top 15 features that retained 99% of the performance of the full feature set while reducing the training time by 73%. These findings highlight the feasibility of a portable ECG-IPG system for sleep staging, balancing accuracy and computational efficiency. The proposed approach has the potential to enable continuous sleep monitoring and personalized health management in real-world applications.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2025-06-17
DOI
https://doi.org/10.1016/j.compbiomed.2025.110452
Citations
2
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
2.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patch-type wearable electrocardiography and impedance pneumography for sleep staging: A multi-modal deep learning approach

In Cheol Jeong, Sunghan Lee, Ung Park, Sung Pil Cho et al.
2 citations
Computers in Biology and Medicine
Obstructive Sleep Apnea Research
2.33
article

Patch-type wearable electrocardiography and impedance pneumography for sleep staging: A multi-modal deep learning approach

In Cheol Jeong, Sunghan Lee, Ung Park, Sung Pil Cho, Goeun Park, Suyeon Yun, Kyung Min Kim
article en
2 citations

Abstract

Sleep staging is critical for investigating sleep quality and detecting disorders. Polysomnography (PSG) remains the gold standard, but is costly and impractical for routine monitoring. This study evaluates the feasibility of a patch-type wearable device using single-lead electrocardiography (ECG) and impedance pneumography (IPG) for multi-stage sleep classification. Data from 92 patients were collected using a wearable ECG-IPG device. Preprocessing entailed bandpass filtering, segmentation into 5-min windows with 30-s overlaps, and feature extraction in time, frequency, and nonlinear domains. Three classification methods were tested and validated using 5-fold patient-independent cross-validation across 2-class (Wake, Sleep), 3-class (Wake, rapid eye movement (REM), and Non-REM), and 4-class (Wake, REM, N1, and N2) tasks. The combined approach achieved the highest accuracy in the 2-class task (accuracy: 83.6%, area under the receiver operating characteristic (AUROC): 86.0%). For 3- and 4-class tasks, feature-based methods outperformed the others, with the RCNN achieving the best F1-score (0.618 in 3-class and 0.552 in 4-class). Modality analysis revealed that IPG + R-R interval (RRI) + motion sensors provided the highest performance, with IPG and RRI identified as the most effective in sleep staging. Feature reduction using maximum relevance and minimum redundancy (mRMR) identified the top 15 features that retained 99% of the performance of the full feature set while reducing the training time by 73%. These findings highlight the feasibility of a portable ECG-IPG system for sleep staging, balancing accuracy and computational efficiency. The proposed approach has the potential to enable continuous sleep monitoring and personalized health management in real-world applications.

Computers in Biology and MedicineVol. 195
Hallym University (KR), Daewoo Electronics (South Korea) (KR), Severance Hospital (KR), Gangnam Severance Hospital (KR), Yonsei University Health System (KR)
Openalex Percentile: Top 12%
Obstructive Sleep Apnea Research
2.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.