Design and Simulation of a Captive Grid-Tied Solar PV System for Daytime Peak Load Management: A Case Study of Maasai Mara University

Aims: To develop an optimal electricity consumption profile for Maasai Mara University based on 90 days actual consumption data. To design and simulate captive grid interactive solar photovoltaic system for Maasai Mara University based on the first objective. Study Design: The system was designed and simulated using PV*Sol software to determine monthly energy production. Place and Duration of Study: A captive grid-tied solar PV system for the rooftop of the kitchen square at Maasai Mara University, for the daytime peak load that occurs usually between 10:00 AM and 2:00 PM. Methodology: Maasai Mara University consumption load data was collected using a data logging system by the use of a special meter, acuvim ii meter. Initial system sizing was performed using the PV Sizing Agent tool. A 141-KW panel system was sized. A detailed 3D model was designed utilizing 203 Jinko JKM629N-66HL-5-BDV photovoltaic panels, each with a rated power of 695W Silicon Monocrystalline panels and a total of 14 SMA inverters were strategically chosen, with different models selected to match the specific characteristics of each PV array. Results: Analysis of the university’s energy consumption profile revealed a Peak Load Value, 102KW peak demand. The simulated PV system is projected to generate 249,576.20 kWh of electricity in a year, of this 78.1% is directly consumed on-site, fulfilling 50.07% of the university's appliance load, demonstrating the potential for significant peak load reduction within institutional settings. Conclusion: A financial analysis of the designed system was done, the financial analysis obtained a net present value of Ksh.8.058988704×107 for the solar PV system with an Internal Rate of Return (IRR) of 26.735% and a payback period of 4 years. This study highlights the feasibility of cost-effective, sustainable solar energy solutions for universities.

Authors

Institutions

Publication Details

Journal
Asian Journal of Research and Reviews in Physics
Published
2025-06-17
DOI
https://doi.org/10.9734/ajr2p/2025/v9i3196
Citations
1
Primary Topic
Smart Grid Energy Management
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Simulation of a Captive Grid-Tied Solar PV System for Daytime Peak Load Management: A Case Study of Maasai Mara University

Duke Oeba, Justus Simiyu, Dorothy Atieno Lwambe, Otieno Fredrick
1 citations
Asian Journal of Research and Reviews in Physics
Smart Grid Energy Management
0.73
article

Design and Simulation of a Captive Grid-Tied Solar PV System for Daytime Peak Load Management: A Case Study of Maasai Mara University

Duke Oeba, Justus Simiyu, Dorothy Atieno Lwambe, Otieno Fredrick
article en
1 citations

Abstract

Aims: To develop an optimal electricity consumption profile for Maasai Mara University based on 90 days actual consumption data. To design and simulate captive grid interactive solar photovoltaic system for Maasai Mara University based on the first objective. Study Design: The system was designed and simulated using PV*Sol software to determine monthly energy production. Place and Duration of Study: A captive grid-tied solar PV system for the rooftop of the kitchen square at Maasai Mara University, for the daytime peak load that occurs usually between 10:00 AM and 2:00 PM. Methodology: Maasai Mara University consumption load data was collected using a data logging system by the use of a special meter, acuvim ii meter. Initial system sizing was performed using the PV Sizing Agent tool. A 141-KW panel system was sized. A detailed 3D model was designed utilizing 203 Jinko JKM629N-66HL-5-BDV photovoltaic panels, each with a rated power of 695W Silicon Monocrystalline panels and a total of 14 SMA inverters were strategically chosen, with different models selected to match the specific characteristics of each PV array. Results: Analysis of the university’s energy consumption profile revealed a Peak Load Value, 102KW peak demand. The simulated PV system is projected to generate 249,576.20 kWh of electricity in a year, of this 78.1% is directly consumed on-site, fulfilling 50.07% of the university's appliance load, demonstrating the potential for significant peak load reduction within institutional settings. Conclusion: A financial analysis of the designed system was done, the financial analysis obtained a net present value of Ksh.8.058988704×107 for the solar PV system with an Internal Rate of Return (IRR) of 26.735% and a payback period of 4 years. This study highlights the feasibility of cost-effective, sustainable solar energy solutions for universities.

Asian Journal of Research and Reviews in PhysicsVol. 9(3)
Egerton University (KE), Maasai Mara University (KE)
Openalex Percentile: Top 27%
Smart Grid Energy Management
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.