Low-Cost Robust Detection Method of Interturn Short-Circuit Fault for Distribution Transformer Based on ΔU-I Locus Characteristic

Winding interturn short-circuit (ISCF) fault is a common problem which occurs in distribution transformers due to multiple internal and external factors. Unfortunately, the variations in electric parameters under a slight fault are tiny and hardly used as effective characteristics for the detection and protection system. To address this issue, a low-cost robust detection method of ISCF based on the port voltage–current (ΔU-I) locus characteristic is presented in this paper. The mathematical model of the three-phase distribution transformer with ISCF is first established. Then, the ΔU-I locus function and relevant characteristic parameters are analyzed, respectively, which can reflect the healthy and faulty conditions. The axis length ratio between the major axis length and the minor axis length in the ΔU-I ellipse curve is defined as the fault indicator for the sensitivity and robustness of fault diagnosis. Moreover, this method can reduce the number of sensors and has strong robustness against load fluctuations. In the end, the theoretical analysis and simulation results verify the effectiveness of the ΔU-I locus characteristic.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-06-17
DOI
https://doi.org/10.3390/electronics14122458
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Cost Robust Detection Method of Interturn Short-Circuit Fault for Distribution Transformer Based on ΔU-I Locus Characteristic

Jinwei Lin, Zhu Han, Jialei Hu, Yonghao Sun et al.
Electronics
Power Systems Fault Detection
article

Low-Cost Robust Detection Method of Interturn Short-Circuit Fault for Distribution Transformer Based on ΔU-I Locus Characteristic

Jinwei Lin, Zhu Han, Jialei Hu, Yonghao Sun, Wei Wang, Yunlong Wang, Tao Ji
article en

Abstract

Winding interturn short-circuit (ISCF) fault is a common problem which occurs in distribution transformers due to multiple internal and external factors. Unfortunately, the variations in electric parameters under a slight fault are tiny and hardly used as effective characteristics for the detection and protection system. To address this issue, a low-cost robust detection method of ISCF based on the port voltage–current (ΔU-I) locus characteristic is presented in this paper. The mathematical model of the three-phase distribution transformer with ISCF is first established. Then, the ΔU-I locus function and relevant characteristic parameters are analyzed, respectively, which can reflect the healthy and faulty conditions. The axis length ratio between the major axis length and the minor axis length in the ΔU-I ellipse curve is defined as the fault indicator for the sensitivity and robustness of fault diagnosis. Moreover, this method can reduce the number of sensors and has strong robustness against load fluctuations. In the end, the theoretical analysis and simulation results verify the effectiveness of the ΔU-I locus characteristic.

ElectronicsVol. 14(12)
State Grid Corporation of China (China) (CN), Southeast University (CN)
Openalex Percentile: Top 85%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.