A Novel Modification Of Manual Vacuum Aspiration Technique Guided By Ultrasound For Safe And Effective Abortion Management

Background: Manual vacuum aspiration (MVA) is a widely used technique for first-trimester pregnancy termination. However, conventional MVA involves back-and-forth cannula movements while turning 360°rotational, which may increase procedural complexity and risk of complications. This study introduces a novel MVA modification using continuous only 360° rotational cannula movement under real-time ultrasound (USG) guidance, hypothesized to improve safety and efficacy. Methods: In this retrospective observational pilot study conducted at Stella Maris Women’s and Children’s Hospital (Medan, Indonesia) from January 2024 to January 2025, 60 patients with missed abortion ≤8 weeks gestation were allocated into two groups: conventional ultrasound-guided MVA (USGMVA) and rotational USG-MVA without back-and-forth cannula motion. Procedures were performed by a single experienced gynecologist. Outcomes assessed included pain scores, blood loss, procedure time, laceration, retained of conception, pelvic inflammatory disease (PID) and uterine perforation. Results: The rotational USG-MVA group reported significantly lower pain scores (2.13 ± 0.78 vs. 3.01 ± 1.48, p=0.003), shorter procedure time (8.87 ± 0.68 min vs. 9.67 ± 1.97 min, p=0.040), reduced cervical laceration (0.00 ± 0 vs 0.13 ± 0.31, p = 0.043), lower blood loss (27.27 ± 2.78 mL vs. 30.77 ± 4.77 mL; p = 0.001) and the number of aspirations required was fewer in the rotational USG-MVA group (3.8 ± 0.74 vs. 4.3 ± 0.92; p = 0.035). No cases of uterine perforation, pelvic inflammatory disease, or retained products of conception occurred in either group. Conclusion: The novel rotational MVA technique perfomed under USG guidance is a safe, effective and user-friendly alternative to conventional MVA.

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2025-01-01
DOI
https://doi.org/10.53555/ajbr.v28i3s.7893
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Modification Of Manual Vacuum Aspiration Technique Guided By Ultrasound For Safe And Effective Abortion Management

Hilma Putri Lubis, Binarwan Halim, Syalma Kurnia Nur Andini
African Journal of Biomedical Research
Ultrasound and Hyperthermia Applications
article

A Novel Modification Of Manual Vacuum Aspiration Technique Guided By Ultrasound For Safe And Effective Abortion Management

Hilma Putri Lubis, Binarwan Halim, Syalma Kurnia Nur Andini
article en

Abstract

Background: Manual vacuum aspiration (MVA) is a widely used technique for first-trimester pregnancy termination. However, conventional MVA involves back-and-forth cannula movements while turning 360°rotational, which may increase procedural complexity and risk of complications. This study introduces a novel MVA modification using continuous only 360° rotational cannula movement under real-time ultrasound (USG) guidance, hypothesized to improve safety and efficacy. Methods: In this retrospective observational pilot study conducted at Stella Maris Women’s and Children’s Hospital (Medan, Indonesia) from January 2024 to January 2025, 60 patients with missed abortion ≤8 weeks gestation were allocated into two groups: conventional ultrasound-guided MVA (USGMVA) and rotational USG-MVA without back-and-forth cannula motion. Procedures were performed by a single experienced gynecologist. Outcomes assessed included pain scores, blood loss, procedure time, laceration, retained of conception, pelvic inflammatory disease (PID) and uterine perforation. Results: The rotational USG-MVA group reported significantly lower pain scores (2.13 ± 0.78 vs. 3.01 ± 1.48, p=0.003), shorter procedure time (8.87 ± 0.68 min vs. 9.67 ± 1.97 min, p=0.040), reduced cervical laceration (0.00 ± 0 vs 0.13 ± 0.31, p = 0.043), lower blood loss (27.27 ± 2.78 mL vs. 30.77 ± 4.77 mL; p = 0.001) and the number of aspirations required was fewer in the rotational USG-MVA group (3.8 ± 0.74 vs. 4.3 ± 0.92; p = 0.035). No cases of uterine perforation, pelvic inflammatory disease, or retained products of conception occurred in either group. Conclusion: The novel rotational MVA technique perfomed under USG guidance is a safe, effective and user-friendly alternative to conventional MVA.

African Journal of Biomedical Research
Gender equality
Openalex Percentile: Top 87%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.