Non-enzymatic electrochemical sensor for uric acid based on surfactant-silica-MWCNT nanohybrids functionalized with APTES

The CTAB@SiO 2 @MWCNT-APTES composite was synthesized and applied as a modifier for a glassy carbon electrode (GCE) for the electrochemical the determination of uric acid (UA). APTES was successfully immobilized on multi-walled carbon nanotubes (MWCNTs) through non-covalent hydrophobic interactions and formed a nanoscale network that enhanced electron transfer and access to the detection sites. All experimental parameters were optimized, and the modified sensor exhibited a linear detection range from 5 × 10⁻⁹ to 1 × 10⁻⁸ molL⁻¹ and from 1.25 × 10⁻⁸ to 1.0 × 10 -7 molL⁻¹, a high sensitivity of 2.7 × 10⁷ µA·mol⁻¹L, and a low detection limit (LOD) of approximately 4.5×10⁻ 10 molL⁻¹. Structural characterization by FTIR, EDX and transmission electron microscopy confirmed the integrity and successful functionalization of the composite. The CTAB@SiO 2 @MWCNT-APTES-modified electrode allowed clear separation of the uric acid oxidation peak from common interfering species such as ascorbic acid and dopamine. The sensor was effectively applied to human plasma and urine samples, achieving recovery rates between 92% and 104%, confirming its potential for reliable real-sample analysis and future sensor development. • CTAB@SiO2@MWCNT-APTES composite is synthesized and characterized by FTIR and TEM • The CTAB@SiO2@MWCNT-APTES composite enhanced the electrochemical detection of uric acid. • The sensor exhibited high stability, compatibility, and selectivity in analyte detection. • A recovery of 92%-104% was achieved in plasma and urine, validating its analytical efficacy.

Authors

Institutions

Publication Details

Journal
Colloids and Surfaces A Physicochemical and Engineering Aspects
Published
2025-06-17
DOI
https://doi.org/10.1016/j.colsurfa.2025.137520
Citations
13
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
9.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-enzymatic electrochemical sensor for uric acid based on surfactant-silica-MWCNT nanohybrids functionalized with APTES

Soledad Carinelli, Houcine Barhoumi, Michael Holzinger, Pedro Salazar et al.
13 citations
Colloids and Surfaces A Physicochemical and Engineering Aspects
Electrochemical sensors and biosensors
9.50
article

Non-enzymatic electrochemical sensor for uric acid based on surfactant-silica-MWCNT nanohybrids functionalized with APTES

Soledad Carinelli, Houcine Barhoumi, Michael Holzinger, Pedro Salazar, Afef Dhaffouli
article en
13 citations

Abstract

The CTAB@SiO 2 @MWCNT-APTES composite was synthesized and applied as a modifier for a glassy carbon electrode (GCE) for the electrochemical the determination of uric acid (UA). APTES was successfully immobilized on multi-walled carbon nanotubes (MWCNTs) through non-covalent hydrophobic interactions and formed a nanoscale network that enhanced electron transfer and access to the detection sites. All experimental parameters were optimized, and the modified sensor exhibited a linear detection range from 5 × 10⁻⁹ to 1 × 10⁻⁸ molL⁻¹ and from 1.25 × 10⁻⁸ to 1.0 × 10 -7 molL⁻¹, a high sensitivity of 2.7 × 10⁷ µA·mol⁻¹L, and a low detection limit (LOD) of approximately 4.5×10⁻ 10 molL⁻¹. Structural characterization by FTIR, EDX and transmission electron microscopy confirmed the integrity and successful functionalization of the composite. The CTAB@SiO 2 @MWCNT-APTES-modified electrode allowed clear separation of the uric acid oxidation peak from common interfering species such as ascorbic acid and dopamine. The sensor was effectively applied to human plasma and urine samples, achieving recovery rates between 92% and 104%, confirming its potential for reliable real-sample analysis and future sensor development. • CTAB@SiO2@MWCNT-APTES composite is synthesized and characterized by FTIR and TEM • The CTAB@SiO2@MWCNT-APTES composite enhanced the electrochemical detection of uric acid. • The sensor exhibited high stability, compatibility, and selectivity in analyte detection. • A recovery of 92%-104% was achieved in plasma and urine, validating its analytical efficacy.

Colloids and Surfaces A Physicochemical and Engineering AspectsVol. 724
Centre National de la Recherche Scientifique (FR), Universidad de La Laguna (ES), University of Monastir (TN), University of Gafsa (TN), Instituto de Neurociencias (ES), Université Grenoble Alpes (FR)
Openalex Percentile: Top 2%
Electrochemical sensors and biosensors
9.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.