Accuracy improving research on the calibration methods of organic scintillator detectors

The calibration accuracy of the response matrix has a critical effect on the accuracy and stability of the unfolded spectra of organic scintillator neutron spectrometers. In this paper, based on the calibration of an EJ-301 liquid scintillation detector, several optimization methods were proposed to improve the calibration accuracy. For gamma calibration, the influence of different coincidence components on the peak energies of the coincidence spectra was studied using Monte Carlo simulation, and the errors introduced by treating coincidence spectra as peaks of monoenergetic electrons in traditional methods were corrected by a well-designed iterative comparison method; the effect of electronic response nonlinearity on the Monte Carlo iterative calibration method was studied and then taken into account to further improve the calibration accuracy, reducing the relative deviation of the response to 4.438 MeV γ-rays from 3.31% to 0.61%. For neutron calibration, the calibration method based on isotope neutron sources and the time-of-flight technique was optimized under low-count conditions using an ionization quenching model. Finally, the calibration effect was validated using a DT neutron generator, and the results demonstrated that the methods proposed in this paper can significantly improve the calibration accuracy.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-06-17
DOI
https://doi.org/10.1016/j.net.2025.103757
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy improving research on the calibration methods of organic scintillator detectors

Zhimeng Hu, Lin-Jun Hou, Wenqi Yu, Peng Xu
Nuclear Engineering and Technology
Radiation Detection and Scintillator Technologies
article

Accuracy improving research on the calibration methods of organic scintillator detectors

Zhimeng Hu, Lin-Jun Hou, Wenqi Yu, Peng Xu
article en

Abstract

The calibration accuracy of the response matrix has a critical effect on the accuracy and stability of the unfolded spectra of organic scintillator neutron spectrometers. In this paper, based on the calibration of an EJ-301 liquid scintillation detector, several optimization methods were proposed to improve the calibration accuracy. For gamma calibration, the influence of different coincidence components on the peak energies of the coincidence spectra was studied using Monte Carlo simulation, and the errors introduced by treating coincidence spectra as peaks of monoenergetic electrons in traditional methods were corrected by a well-designed iterative comparison method; the effect of electronic response nonlinearity on the Monte Carlo iterative calibration method was studied and then taken into account to further improve the calibration accuracy, reducing the relative deviation of the response to 4.438 MeV γ-rays from 3.31% to 0.61%. For neutron calibration, the calibration method based on isotope neutron sources and the time-of-flight technique was optimized under low-count conditions using an ionization quenching model. Finally, the calibration effect was validated using a DT neutron generator, and the results demonstrated that the methods proposed in this paper can significantly improve the calibration accuracy.

Nuclear Engineering and TechnologyVol. 57(11)
Horological Research Institute of Light Industry (CN), Nanjing University of Aeronautics and Astronautics (CN)
Openalex Percentile: Top 80%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy improving research on the calibration methods of organic scintillator detectors — Zhimeng Hu, Lin-Jun Hou, et al. · Nuclear Engineering and Technology (2025) | TGRS Research Map | TGRS