Design, development, and evaluation of a novel shoulder phantom testbed for analyzing interaction forces and reachability of wearable exoskeletons

The human need for rehabilitation, assistance, and augmentation has led to the development and use of wearable exoskeletons. Upper limb exoskeletons under research and development are tested on human volunteers to gauge performance and usability. Direct testing can often cause straining of the joints, especially the shoulder joint, which is the most important and flexible joint in the upper extremity of the human body. The misalignment of joint axes between the exoskeleton and the human body causes straining. To avoid this, we propose designing and developing a novel human shoulder phantom mimicking the shoulder complex motion and the humeral head translation that can help in the real-time testing of exoskeletons without the need for human volunteers. The device can be used to test the interaction forces and the maximum reachable position of the exoskeleton. It consists of three degrees of freedom (DOF) passive shoulder girdle mechanism and seven DOF glenohumeral joint mechanisms, of which six are passive revolute joints and one is an active prismatic joint mimicking the humeral head translation. All the passive joints are spring-loaded and are incorporated with joint angle sensors. A custom-made, three-axis force sensor measures the human-exoskeleton interaction forces. The design details, selection of joint springs, linear actuation mechanism, and the analysis of the phantom's reachable workspace are presented. The device is validated by comparing the interaction forces produced during the conventional exoskeleton-assisted and human-assisted phantom arm elevation.

Authors

Institutions

Publication Details

Journal
Wearable Technologies
Published
2025-01-01
DOI
https://doi.org/10.1017/wtc.2025.10006
Citations
1
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design, development, and evaluation of a novel shoulder phantom testbed for analyzing interaction forces and reachability of wearable exoskeletons

Santhakumar Mohan, Avinash S Pramod, Asokan Thondiyath, R. N. Adithya
1 citations
Wearable Technologies
Shoulder Injury and Treatment
2.01
article

Design, development, and evaluation of a novel shoulder phantom testbed for analyzing interaction forces and reachability of wearable exoskeletons

Santhakumar Mohan, Avinash S Pramod, Asokan Thondiyath, R. N. Adithya
article en
1 citations

Abstract

The human need for rehabilitation, assistance, and augmentation has led to the development and use of wearable exoskeletons. Upper limb exoskeletons under research and development are tested on human volunteers to gauge performance and usability. Direct testing can often cause straining of the joints, especially the shoulder joint, which is the most important and flexible joint in the upper extremity of the human body. The misalignment of joint axes between the exoskeleton and the human body causes straining. To avoid this, we propose designing and developing a novel human shoulder phantom mimicking the shoulder complex motion and the humeral head translation that can help in the real-time testing of exoskeletons without the need for human volunteers. The device can be used to test the interaction forces and the maximum reachable position of the exoskeleton. It consists of three degrees of freedom (DOF) passive shoulder girdle mechanism and seven DOF glenohumeral joint mechanisms, of which six are passive revolute joints and one is an active prismatic joint mimicking the humeral head translation. All the passive joints are spring-loaded and are incorporated with joint angle sensors. A custom-made, three-axis force sensor measures the human-exoskeleton interaction forces. The design details, selection of joint springs, linear actuation mechanism, and the analysis of the phantom's reachable workspace are presented. The device is validated by comparing the interaction forces produced during the conventional exoskeleton-assisted and human-assisted phantom arm elevation.

Wearable TechnologiesVol. 6
Johns Hopkins University (US), Indian Institute of Technology Madras (IN), Johns Hopkins Medicine (US), Indian Institute of Technology Palakkad (IN)
Openalex Percentile: Top 15%
Shoulder Injury and Treatment
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.