O-Arm Vs Surgivisio for Pedicle Screw Insertion: A Prospective Study on Screw Accuracy and Irradiation on 100 Patients

<h3>Background</h3> Computerized navigation improves the accuracy of spine procedures. However, intraoperative imaging is plagued by ionizing irradiation and its cancer risk. Advanced technologies attempt to optimize the radiation dose. The goal of this study was to compare radiation exposure and screw accuracy of O-arm navigation and the Surgivisio device (SD) in pedicle screw insertion. <h3>Methods</h3> All patients operated on by navigated pedicle screw insertion during a 19-month period were prospectively included in 2 spine centers: the first with the O-arm and the second with the SD. Demographic, operative, and irradiation data were collected. The accuracy of the screw positioning was assessed using the Heary and Gertzbein classifications. The effective dose in millisievert (mSv) was calculated. <h3>Results</h3> One hundred patients were included, 50 per group. Five hundred and twelve screws were inserted, among them 228 in 120 vertebrae with the O-am and 284 in 145 vertebrae with the SD. Screw accuracy was 99.1% with the O-arm vs 93.3% with the SD (<i>P</i> = 0.07). Operative times were similar, with 145 vs 139 minutes respectively, <i>P</i> = 0.68. The effective dose was significantly higher in the O-arm group, with 5.43 vs 2.70 mSv with the SD (<i>P</i> &lt; 0.01). The effective dose related to 2-dimensional imaging was significantly lower in the O-arm group than in the SD group, with 0.26 vs 1.16 mSv, respectively, <i>P</i> &lt; 0.01, related to a shorter imaging duration (4 vs 109 seconds respectively, <i>P</i> &lt; 0.01). <h3>Conclusions</h3> Accuracy of pedicle screws was higher with the O-arm than with the Surgivisio, but the latter showed less radiation exposure. Despite promising results, improvements in technology should be pursued for ergonomics and surgical safety. <h3>Level of Evidence</h3> 4.

Authors

Institutions

Publication Details

Journal
The International Journal of Spine Surgery
Published
2025-06-17
DOI
https://doi.org/10.14444/8766
Citations
1
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O-Arm Vs Surgivisio for Pedicle Screw Insertion: A Prospective Study on Screw Accuracy and Irradiation on 100 Patients

Guillaume Cavalié, Mehdi Boudissa, Maxime Saad, Jérôme Tonetti et al.
1 citations
The International Journal of Spine Surgery
Spinal Fractures and Fixation Techniques
2.01
article

O-Arm Vs Surgivisio for Pedicle Screw Insertion: A Prospective Study on Screw Accuracy and Irradiation on 100 Patients

Guillaume Cavalié, Mehdi Boudissa, Maxime Saad, Jérôme Tonetti, Jean-Loup Gassend, Gaël Kerschbaumer, Marc Prod’homme, Arun Prakash Thangavelu
article en
1 citations

Abstract

<h3>Background</h3> Computerized navigation improves the accuracy of spine procedures. However, intraoperative imaging is plagued by ionizing irradiation and its cancer risk. Advanced technologies attempt to optimize the radiation dose. The goal of this study was to compare radiation exposure and screw accuracy of O-arm navigation and the Surgivisio device (SD) in pedicle screw insertion. <h3>Methods</h3> All patients operated on by navigated pedicle screw insertion during a 19-month period were prospectively included in 2 spine centers: the first with the O-arm and the second with the SD. Demographic, operative, and irradiation data were collected. The accuracy of the screw positioning was assessed using the Heary and Gertzbein classifications. The effective dose in millisievert (mSv) was calculated. <h3>Results</h3> One hundred patients were included, 50 per group. Five hundred and twelve screws were inserted, among them 228 in 120 vertebrae with the O-am and 284 in 145 vertebrae with the SD. Screw accuracy was 99.1% with the O-arm vs 93.3% with the SD (<i>P</i> = 0.07). Operative times were similar, with 145 vs 139 minutes respectively, <i>P</i> = 0.68. The effective dose was significantly higher in the O-arm group, with 5.43 vs 2.70 mSv with the SD (<i>P</i> &lt; 0.01). The effective dose related to 2-dimensional imaging was significantly lower in the O-arm group than in the SD group, with 0.26 vs 1.16 mSv, respectively, <i>P</i> &lt; 0.01, related to a shorter imaging duration (4 vs 109 seconds respectively, <i>P</i> &lt; 0.01). <h3>Conclusions</h3> Accuracy of pedicle screws was higher with the O-arm than with the Surgivisio, but the latter showed less radiation exposure. Despite promising results, improvements in technology should be pursued for ergonomics and surgical safety. <h3>Level of Evidence</h3> 4.

The International Journal of Spine SurgeryVol. 19(4)
Centre Hospitalier Universitaire de Grenoble (FR), University Centre of Legal Medicine (CH), Clinique de La Source (CH), The Spine Institute (US), Pädagogische Hochschule Wallis (CH), Agir Pour les Maladies Chroniques (FR), Centre d'Investigation Clinique Pierre Drouin (FR), Université Grenoble Alpes (FR)
Openalex Percentile: Top 15%
Spinal Fractures and Fixation Techniques
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.