Analisis Pengaruh Penggunaan Physical Wedge Filter pada Dose Profile dan Percentage Depth Dose Pesawat Radioterapi Clinax-Cx di Rumah Sakit Universitas Andalas

A study has been conducted on the effect of using a physical wedge filter on the dose profile and Percentage Depth Dose (PDD) of the CLINAC-CX teletherapy device at Andalas University Hospital. This study aims to determine the shape of the dose profile and PDD curves formed from the use of physical wedges. Measurements were made with variations in photon beam energy (6 MV and 10 MV) and variations in the angle of the physical wedge filter (15°, 30°, 45°, and 60°). Data processing begins by calculating incomplete data from the LINAC using interpolation techniques. The data is then displayed in the form of a curve or graph using Microsoft Excel. The results of the PDD curve measurement showed no significant difference in the curve formed using or without a wedge. The resulting zmax did not differ much from each other, where for a 6 MV beam without a wedge it was 13.8 mm while the average wedge variation was 14.72 mm. The 10 MV beam variation showed a value of 23.4 mm and an average of 24 mm. The dose profile formed is influenced by the use of wedge, the comparison of the smallest and largest symmetry, flatness, and penumbra values. The smallest values ​​at 6 MV irradiation without wedge are respectively 2.1%, 3.1%, 7.1 mm, and 7.3 mm, while the largest with a wedge angle of 60°, 32.4%, 58.3%, 15.8 mm. The wedge factor between 6 MV and 10 MV shows no difference.

Authors

Institutions

Publication Details

Journal
Jurnal Fisika Unand
Published
2025-05-08
DOI
https://doi.org/10.25077/jfu.14.2.184-190.2025
Primary Topic
Computer Science and Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Pengaruh Penggunaan Physical Wedge Filter pada Dose Profile dan Percentage Depth Dose Pesawat Radioterapi Clinax-Cx di Rumah Sakit Universitas Andalas

Rico Adrial, Mohammad Randy Alhafiz
Jurnal Fisika Unand
Computer Science and Engineering
article

Analisis Pengaruh Penggunaan Physical Wedge Filter pada Dose Profile dan Percentage Depth Dose Pesawat Radioterapi Clinax-Cx di Rumah Sakit Universitas Andalas

Rico Adrial, Mohammad Randy Alhafiz
article en

Abstract

A study has been conducted on the effect of using a physical wedge filter on the dose profile and Percentage Depth Dose (PDD) of the CLINAC-CX teletherapy device at Andalas University Hospital. This study aims to determine the shape of the dose profile and PDD curves formed from the use of physical wedges. Measurements were made with variations in photon beam energy (6 MV and 10 MV) and variations in the angle of the physical wedge filter (15°, 30°, 45°, and 60°). Data processing begins by calculating incomplete data from the LINAC using interpolation techniques. The data is then displayed in the form of a curve or graph using Microsoft Excel. The results of the PDD curve measurement showed no significant difference in the curve formed using or without a wedge. The resulting zmax did not differ much from each other, where for a 6 MV beam without a wedge it was 13.8 mm while the average wedge variation was 14.72 mm. The 10 MV beam variation showed a value of 23.4 mm and an average of 24 mm. The dose profile formed is influenced by the use of wedge, the comparison of the smallest and largest symmetry, flatness, and penumbra values. The smallest values ​​at 6 MV irradiation without wedge are respectively 2.1%, 3.1%, 7.1 mm, and 7.3 mm, while the largest with a wedge angle of 60°, 32.4%, 58.3%, 15.8 mm. The wedge factor between 6 MV and 10 MV shows no difference.

Jurnal Fisika UnandVol. 14(2)
Andalas University (ID)
Openalex Percentile: Top 93%
Computer Science and Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.