[23]Crown Ether Incorporating Metastable [2]Rotaxanes and Pseudo[2]rotaxanes: Selective and Sensitive Fluoride Anion Detection with 4‐Isopropylphenyl Stoppered [2]Rotaxane

Two metastable [2]rotaxanes incorporating [23]crown-7-ether, with cyclohexyl and 4-isopropylphenyl slippage stoppers, are explored. The axle component of metastable rotaxanes is comprised of a secondary ammonium station and an anthracene fluorophore. In the presence of fluoride anion, the deslippage of [23]crown-7-ether over the slippage stoppers is induced by ion-pair formation with fluoride anion, followed by neutralization. Both the rotaxanes displayed highly selective fluoride anion responsiveness, however, 4-isopropylphenyl being less bulky, exhibited more sensitive fluoride anion detection in acetonitrile-water medium. The addition of excess TBACl, TBABr, and TBAI did not invoke any switching response in acetonitrile-water medium (v/v = 99:1, 98:2, and 97:3). Furthermore, the metastable [2]rotaxane with a 4-isopropylphenyl slippage stopper could successfully detect ionic fluoride anions such as potassium fluoride and cesium fluoride well below the W.H.O. permissible limit. In addition, [23]crown-7-ether generated pseudo[2]rotaxane complexes with a series of ammonium axles comprised of variable terminal groups.

Authors

Institutions

Publication Details

Journal
Chemistry - An Asian Journal
Published
2025-06-17
DOI
https://doi.org/10.1002/asia.202401680
Citations
1
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

[23]Crown Ether Incorporating Metastable [2]Rotaxanes and Pseudo[2]rotaxanes: Selective and Sensitive Fluoride Anion Detection with 4‐Isopropylphenyl Stoppered [2]Rotaxane

Suvankar Dasgupta, Mukesh Jaiswal
1 citations
Chemistry - An Asian Journal
Molecular Sensors and Ion Detection
0.76
article

[23]Crown Ether Incorporating Metastable [2]Rotaxanes and Pseudo[2]rotaxanes: Selective and Sensitive Fluoride Anion Detection with 4‐Isopropylphenyl Stoppered [2]Rotaxane

Suvankar Dasgupta, Mukesh Jaiswal
article en
1 citations

Abstract

Two metastable [2]rotaxanes incorporating [23]crown-7-ether, with cyclohexyl and 4-isopropylphenyl slippage stoppers, are explored. The axle component of metastable rotaxanes is comprised of a secondary ammonium station and an anthracene fluorophore. In the presence of fluoride anion, the deslippage of [23]crown-7-ether over the slippage stoppers is induced by ion-pair formation with fluoride anion, followed by neutralization. Both the rotaxanes displayed highly selective fluoride anion responsiveness, however, 4-isopropylphenyl being less bulky, exhibited more sensitive fluoride anion detection in acetonitrile-water medium. The addition of excess TBACl, TBABr, and TBAI did not invoke any switching response in acetonitrile-water medium (v/v = 99:1, 98:2, and 97:3). Furthermore, the metastable [2]rotaxane with a 4-isopropylphenyl slippage stopper could successfully detect ionic fluoride anions such as potassium fluoride and cesium fluoride well below the W.H.O. permissible limit. In addition, [23]crown-7-ether generated pseudo[2]rotaxane complexes with a series of ammonium axles comprised of variable terminal groups.

Chemistry - An Asian JournalVol. 20(17)
National Institute of Technology Patna (IN)
Science and Engineering Research Board
Clean water and sanitation
Openalex Percentile: Top 30%
Molecular Sensors and Ion Detection
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.