PBO-FRCM and CFRP strengthened reinforced concrete columns: In fire and post-fire behavior

This paper experimentally investigates the thermal response and post-fire structural behavior of seven short circular reinforced concrete columns. The variables include the type of strengthening system applied polypara-phenylene-benzo-bisthiazole (PBO) fiber-reinforced polymer (FRP) and fabric-reinforced cementitious matrix (FRCM), exposures (unexposed or fire-exposed), and using a cementitious-based Spray-applied Fire Resistive Materials (SFRM) insulation. Four columns were subjected to an ASTM E119 fire without any sustained load during the fire, while the other three columns were unexposed and served as controls. Two months after the fire test, fire-exposed columns were tested under axial loading and compared with unexposed ones. The steel rebar temperature in the insulated FRCM column remained below 150 °C for three hours, while this temperature was over 700 °C for the insulated CFRP-wrapped column. The post-fire axial tests indicated that the fire-exposed, insulated PBO-FRCM wrapped column retained a residual axial capacity of 92 %, significantly higher than the 21–66 % range observed in the other three columns. Considering reduced material properties, ACI code-based predictions for axial capacity showed reasonable accuracy with predicted-to-experimental ratios ranging from 0.86 to 1.16. • PBO-FRCM with SFRM kept steel below 150°C and retained 92% of its original axial capacity after fire. • CFRP adds axial capacity by 87% at room temp vs. 25% for PBO-FRCM, but FRCM retains strength far better in fires.. • Predicted-to-experimental axial capacities ranged from 0.86 to 1.16.

Authors

Institutions

Publication Details

Journal
Construction and Building Materials
Published
2025-06-17
DOI
https://doi.org/10.1016/j.conbuildmat.2025.142306
Citations
4
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
4.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PBO-FRCM and CFRP strengthened reinforced concrete columns: In fire and post-fire behavior

Hamzeh Hajiloo, Sanaz Ramzi, Salem Khalaf, Farid Abed et al.
4 citations
Construction and Building Materials
Structural Behavior of Reinforced Concrete
4.03
article

PBO-FRCM and CFRP strengthened reinforced concrete columns: In fire and post-fire behavior

Hamzeh Hajiloo, Sanaz Ramzi, Salem Khalaf, Farid Abed, Yazan Alhoubi, Ahmed El Refai
article en
4 citations

Abstract

This paper experimentally investigates the thermal response and post-fire structural behavior of seven short circular reinforced concrete columns. The variables include the type of strengthening system applied polypara-phenylene-benzo-bisthiazole (PBO) fiber-reinforced polymer (FRP) and fabric-reinforced cementitious matrix (FRCM), exposures (unexposed or fire-exposed), and using a cementitious-based Spray-applied Fire Resistive Materials (SFRM) insulation. Four columns were subjected to an ASTM E119 fire without any sustained load during the fire, while the other three columns were unexposed and served as controls. Two months after the fire test, fire-exposed columns were tested under axial loading and compared with unexposed ones. The steel rebar temperature in the insulated FRCM column remained below 150 °C for three hours, while this temperature was over 700 °C for the insulated CFRP-wrapped column. The post-fire axial tests indicated that the fire-exposed, insulated PBO-FRCM wrapped column retained a residual axial capacity of 92 %, significantly higher than the 21–66 % range observed in the other three columns. Considering reduced material properties, ACI code-based predictions for axial capacity showed reasonable accuracy with predicted-to-experimental ratios ranging from 0.86 to 1.16. • PBO-FRCM with SFRM kept steel below 150°C and retained 92% of its original axial capacity after fire. • CFRP adds axial capacity by 87% at room temp vs. 25% for PBO-FRCM, but FRCM retains strength far better in fires.. • Predicted-to-experimental axial capacities ranged from 0.86 to 1.16.

Construction and Building MaterialsVol. 489
American University of Sharjah (AE), Université Laval (CA), Carleton University (CA)
American University of Sharjah
Sustainable cities and communities
Openalex Percentile: Top 7%
Structural Behavior of Reinforced Concrete
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.