Ultrasensitive Quantification of Thyroid-Stimulating Hormone and Thyroxine by Nanoelectronic SnS<sub>2</sub> Transistor Sensors

The measurement of thyroid hormones in serum is widely regarded as the most valuable single laboratory tool for assessing thyroid function. This study presents a highly sensitive tin disulfide nanosheet-fabricated field-effect transistor (SnS<sub>2</sub>-FET) designed for the detections of human thyroid-stimulating hormone (hTSH) and thyroxine (T4). By co-modifying an antibody (Ab<sub>TSH</sub> for detecting hTSH), or a DNA aptamer (Apt<sub>T4</sub> for detecting T4), with polyethylene glycol (PEG) on the SnS<sub>2</sub>-FET channel surface, the PEG:Ab<sub>TSH</sub>/SnS<sub>2</sub>-FET and PEG:Apt<sub>T4</sub>/SnS<sub>2</sub>-FET devices achieve highly sensitive and selective detections of hTSH and T4, respectively, even in a high ionic strength buffer (1× PBS) or undiluted serum. With a low limit of detection (in the femtomolar level) and a wide linear working range (spanning at least 6 orders of magnitude of analyte concentration), the PEG:Ab<sub>TSH</sub>/SnS<sub>2</sub>-FET immunosensor and PEG:Apt<sub>T4</sub>/SnS<sub>2</sub>-FET aptasensor can detect the hTSH and T4 levels encountered in the spectrum of thyroid disorders. Notably, these specific receptor-modified SnS<sub>2</sub>-FET devices display negligible cross-reactivity with other pituitary hormones or serum components. This research indicates that the nanoelectronic SnS<sub>2</sub>-FET sensor platforms hold significant potential for point-of-care clinical diagnostics, particularly for the ultrasensitive detection and early screening of medical conditions.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-06-17
DOI
https://doi.org/10.1021/acssensors.5c00115
Citations
5
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
3.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive Quantification of Thyroid-Stimulating Hormone and Thyroxine by Nanoelectronic SnS2 Transistor Sensors

Feng-Yi Su, Yit‐Tsong Chen, Ankur Anand, Tse-Hao Chen et al.
5 citations
ACS Sensors
Electrochemical sensors and biosensors
3.65
article

Ultrasensitive Quantification of Thyroid-Stimulating Hormone and Thyroxine by Nanoelectronic SnS2 Transistor Sensors

Feng-Yi Su, Yit‐Tsong Chen, Ankur Anand, Tse-Hao Chen, Y. F. Chen
article en
5 citations

Abstract

The measurement of thyroid hormones in serum is widely regarded as the most valuable single laboratory tool for assessing thyroid function. This study presents a highly sensitive tin disulfide nanosheet-fabricated field-effect transistor (SnS<sub>2</sub>-FET) designed for the detections of human thyroid-stimulating hormone (hTSH) and thyroxine (T4). By co-modifying an antibody (Ab<sub>TSH</sub> for detecting hTSH), or a DNA aptamer (Apt<sub>T4</sub> for detecting T4), with polyethylene glycol (PEG) on the SnS<sub>2</sub>-FET channel surface, the PEG:Ab<sub>TSH</sub>/SnS<sub>2</sub>-FET and PEG:Apt<sub>T4</sub>/SnS<sub>2</sub>-FET devices achieve highly sensitive and selective detections of hTSH and T4, respectively, even in a high ionic strength buffer (1× PBS) or undiluted serum. With a low limit of detection (in the femtomolar level) and a wide linear working range (spanning at least 6 orders of magnitude of analyte concentration), the PEG:Ab<sub>TSH</sub>/SnS<sub>2</sub>-FET immunosensor and PEG:Apt<sub>T4</sub>/SnS<sub>2</sub>-FET aptasensor can detect the hTSH and T4 levels encountered in the spectrum of thyroid disorders. Notably, these specific receptor-modified SnS<sub>2</sub>-FET devices display negligible cross-reactivity with other pituitary hormones or serum components. This research indicates that the nanoelectronic SnS<sub>2</sub>-FET sensor platforms hold significant potential for point-of-care clinical diagnostics, particularly for the ultrasensitive detection and early screening of medical conditions.

ACS SensorsVol. 10(6)
National Yang Ming Chiao Tung University (TW), National Taiwan University (TW), Mackay Memorial Hospital (TW)
Openalex Percentile: Top 7%
Electrochemical sensors and biosensors
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.