Design and Analysis of Induction Coil Magnetometer with Analog Integrator Circuit for Frequencies up to 200 kHz

The output signal of an induction coil sensor depends on the derivative of the measured value. A system consisting of the induction coil and an integrator can be used to restore the original signal. In this paper a magnetometer based on this principle is presented. The integrator circuit consisted of OP177G operational amplifier is analyzed, based on the concept of inverse passive RC differentiator and built-in low frequency stability. The integrator and induction coil characteristics are simulated in LTspice and Ansys Maxwell simulation software, and validated with measurements. The fabricated magnetometer is calibrated in the frequency range from 10 to 200 kHz.

Authors

Institutions

Publication Details

Published
2025-04-21
DOI
https://doi.org/10.1109/smagrimet66590.2025.11030005
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Analysis of Induction Coil Magnetometer with Analog Integrator Circuit for Frequencies up to 200 kHz

Martin Dadić, Mario Filipašić
Magnetic Field Sensors Techniques
article

Design and Analysis of Induction Coil Magnetometer with Analog Integrator Circuit for Frequencies up to 200 kHz

Martin Dadić, Mario Filipašić
article en

Abstract

The output signal of an induction coil sensor depends on the derivative of the measured value. A system consisting of the induction coil and an integrator can be used to restore the original signal. In this paper a magnetometer based on this principle is presented. The integrator circuit consisted of OP177G operational amplifier is analyzed, based on the concept of inverse passive RC differentiator and built-in low frequency stability. The integrator and induction coil characteristics are simulated in LTspice and Ansys Maxwell simulation software, and validated with measurements. The fabricated magnetometer is calibrated in the frequency range from 10 to 200 kHz.

University of Zagreb (HR)
Affordable and clean energy
Openalex Percentile: Top 88%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.